Welcome to ECBAY
40W Switching power supply
40W Switching power supply

Detailed Product Description


  •          Switching power supply,apply to automated control domain 
  •           Low price and high reliability
  •           AC input power suitable for the world
  •           High efficiency and low operation temperature
  •           Soft-start current can reduce the AC input impact effectively
  •           With Short-circuit and overload protection
  •           100% full-load burning test
  •           Installed with EMI filter, minimum wave.
  •           Conform to EN60950 GB4943 UL60950nSafety Standards
  •           2 years warranty

 

Model
Specification

S-40-5

S-40-12

S-40-15

S-40-24

DC output voltage

5V

12V

15V

24V

Output voltage errorNote2

±2%

±1%

±1%

±1%

Rated output current

8A

3.5A

2.8A

1.8A

Output current rage

0-8A

0-3.5A

0-2.8A

0-1.8A

Wave and noise(Note 3

75mVp-p

100mVp-p

100mVp-p

100mVp-p

Inlet stability(Note 4

±0.5%

±0.5%

±0.5%

±0.5%

Load stability (Note 5

±1%

±0.5%

±0.5%

±0.5%

DC output power

40W

42W

42W

43W

Efficiency

72%

76%

77%

78%

Adjustable range for DC voltage

+10,-5%

+10%

+10%

+10%

AC input voltage range

90~132VAC/180-264VAC selected by switch,47-63Hz120-370VDC

Input current

1.2A/115V 0.6A/230V

AC Inrush current

Cold-start current 30A/115V 60A/230V

Leakage current

<1mA/240VAC

Overload protection

105%~150% Tpye:pulsing hiccup shutdown Reset: auto recovery

Temperature coefficient

±0.3%/(0~50%)

Setup rise hold up time

200ms 100ms 30ms

Vibration

10-500HZ,2G 10min,/1cycle,Period for 60min,Each axes

Withstand voltage

Input and output internal1.5KVAC,Input and enclosure1.5KVAC,Output and enclosure0.5KVAC

Isolation resistance

Input and output internal: Input and enclosure, Output and enclosure500VDC/100MΩ

Working temperature and humidity

-10~+60Refer to output derating curve,20%~90%RH

Store temperature and humidity

-20~+85,10%~95%RH

Overall dimension

129×98×38mm

Weight

0.45Kgs

Safety standards

UL1012 TUV6050(IEC,UL1950)Approved

EMC standards

CISPR22(55022),IEC801-2,3,4,IEC555-2 Verification

Note
1.The testing condition for the parameter above is :230VAC input, rated load,2570% RH.Humidity.
2. Error.include the setting error, line stability and load stability. (Note: 5).
3.Wave test: adopting "A12"double wire for 20MHz, and 0.1UF&47UF capacitor short-circuit for interrupting.
4. Inlet voltage stability test: when is over load, the lowest voltage of inlet is up to the highest voltage.
5. Load stability test: the load is from 0% to 100%.
6.C236 must be knocked down.