Welcome to ECBAY
15W ac/dc power supply(Led power)
15W ac/dc power supply(Led power)

Detailed Product Description


  • 15W ac/dc power supply,switch mode design,apply to LED driver
  • Low price and high reliability
  • AC input power suitable for the world
  • High efficiency and low operation temperature
  • Soft-start current can reduce the AC input impact effectively
  • With Short-circuit and overload protection
  • 100% full-load burning test
  • Installed with EMI filter, minimum wave.
  • Conform to EN60950 GB4943 UL60950n Safety Standards
  • 2 years warranty

S-15W series switch mode power supply

Model

S-15-5

S-15-12

S-15-24

DC output voltage

5V

12V

24V

Output voltage errorNote2

±2%

±1%

±1%

Rated output current

3A

1.3A

0.7A

Output current rage

0-3A

0-1.3A

0-0.7A

Wave and noise(Note 3

50mVp-p

50mVp-p

100mVp-p

Inlet stability(Note 4

±0.5%

±0.5%

±0.5%

Load stability (Note 5

±1%

±0.5%

±0.5%

DC output power

15W

15.6W

16.8W

Efficiency

65%

68%

72%

Adjustable range for DC voltage

+10,-5%

+10%

+10%

AC input voltage range

85-132VAC/170-264VAC Selected by switch, 47-63Hz240-370VDC

Input current

0.5A/115V 0.25A/230A

AC INnrush current

Cold-start current 15A /115V 30A/230V

Leakage current

<0.5mA/240VAC

Overload protection

105%-150%Type:Foldback:current limiting reset: auto recovery

Temperature coefficient

±0.02%/0-50

Setup rise hold up time

200ms,100ms,30ms

Vibration

10-500HZ,2G 10min,/1cycle,Period for60min,Each axes

Withstand voltage

Input and output internal1.5KVAC,Input and enclosure1.5KVAC,Output and enclosure0.5KVAC

Isolation resistance

Input and output internal: Input and enclosure, Output and enclosure500VDC/100MΩ

Working temperature and humidity

-10~+60Refer to output derating curve,20%~90%RH

Store temperature and humidity

-20~+85.10%~95%RH

Overall dimension

99×97×35mm

Weight

0.3Kgs

Safety standards

Meet UL 1012 requirement(Not apply for the mark)

EMC standards

Meet FCC part15J Conduction class B

Note
1.The testing condition for the parameter above is :230VAC input, rated load, 2570% RH. Humidity.
2. Error. include the setting error, line stability and load stability. (Note: 5).
3. Wave test: adopting "A12"double wire for 20MHz,and 0.1UF&47UF capacitor short-circuit for interrupting.
4. Inlet voltage stability test: when is over load, the lowest voltage of inlet is up to the highest voltage.
5. Load stability test: the load is from 0% to 100%.

Ads by Google


About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.