Welcome to ECBAY
250W Switching power supply (industrial automatization power supply)
250W Switching power supply (industrial automatization power supply)

Detailed Product Description


  •           250W industrial switching power supply
  •           Low price and high reliability
  •           AC input power suitable for the world
  •           High efficiency and low operation temperature
  •           Soft-start current can reduce the AC input impact effectively
  •           With Short-circuit and overload protection
  •           100% full-load burning test
  •           Installed with EMI filter, minimum wave.
  •           2 years warranty

  S-250W switching power supply

Model

S-250-12

S-250-15

S-250-24

S-250-27

S-250-48

DC output voltage

12V

15V

24V

27V

48V

Output voltage errorNote2

±1%

±1%

±1%

±1%

±1%

Rated output current

20A

15A

10A

9A

5.2A

Output current rage

0-20A

0-15A

0-10A

0-9A

0-5.2A

Wave and noise(Note 3

120mVp-p

120mVp-p

120mVp-p

150mVp-p

200mVp-p

Inlet stability(Note 4

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

Load stability (Note 5

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

DC output power

248W

248W

249W

249W

250W

Efficiency 

79%

80%

81.5%

82%

82%

Adjustable range for DC voltage

10-13.2V

13.5-18V

20-26.4V

26-32V

41-56V

AC input voltage range

85~132VAC/170-264VAC selected by switch, 47-63Hz254-370VDC

Input current

5A/115V  2.5A/230V

AC Inrush current

25A/115V  50A/230V

Leakage current

<3.5mA/240VAC

Overload protection

105%~150% Tpye:pulsing hiccup shutdown Reset: auto recovery

Over-voltage protection

13.8~16.2V

18~21V

27.6~32.4V

33.7~39.2V

57.6~67.2V

High-temperature protection

ERH3≥90, Output shutdown

Temperature coefficient

±0.03%/(0~50%)

Setup rise hold up time

200ms,100ms,20ms

Vibration

10~500Hz,2G 10min,/1cycle,Period for 60min,each axes

Withstand voltage

Input and output internal1.5KVAC,Input and enclosure1.5KVAC,Output and enclosure0.5KVAC

Isolation resistance

Input and output internal: Input and enclosure, Output and enclosure500VDC/100MΩ

Working temperature and humidity

-10~+60Refer to output derating curve,20%~90%RH

Store temperature and humidity

-20~+85,10%~95%RH

Overall dimension

215×115×50mm

Weight

0.95Kgs

Safety standards

Design refer to UL1950

EMC standards

Design refer FCC PART15 J Conduction class A

Note
1.The testing condition for the parameter above is :230VAC input, rated load,2570% RH.Humidity.
2. Error. Include the setting error, line stability and load stability. (Note: 5).
3.Wave test: adopting "A12"double wire for 20MHz, and 0.1UF&47UF capacitor short-circuit for interrupting.
4. Inlet voltage stability test: when is over load, the lowest voltage of inlet is up to the highest voltage.
5. Load stability test: the load is from 0% to 100%.

Ads by Google