Welcome to ECBAY
400W Switching power supply(changing type switch power)
400W Switching power supply(changing type switch power)

Detailed Product Description


  •          400W Switching power supply,changing type switch power 
  •          Low price and high reliability
  •           AC input power suitable for the world
  •           High efficiency and low operation temperature
  •           Soft-start current can reduce the AC input impact effectively
  •           With Short-circuit and overload protection
  •           100% full-load burning test
  •           Installed with EMI filter, minimum wave.
  •           2 years warranty

 

Model

S-400-5

S-400-12

S-400-15

S-400-24

S-400-48

DC output voltage

5V

12V

15V

24V

48V

Output voltage errorNote2

±2%

±1%

±1%

±1%

±1%

Rated output current

60A

33A

27A

17A

8.3A

Output current rage

0-60A

0-33A

0-27A

0-17A

0-8.3A

Wave and noise(Note 3

180mVp-p

180mVp-p

180mVp-p

180mVp-p

240mVp-p

Inlet stability(Note 4

±0.5%

±0.5%

±0.5%

±0.5%

±0.5%

Load stability (Note 5

±1%

±0.5%

±0.5%

±0.5%

±0.5%

DC output power

292W

380W

395W

400W

400W

Efficiency

73%

74%

78%

81%

83%

Adjustable range for DC voltage

4.5-5.6V

10-13.2V

13.5-18V

20-26.4V

41-56V

AC input voltage range

90~132VAC/180-264VAC 47-63Hz254-370VDC

Input current

6.5A/115V 4A/230V

AC Inrush current

25A/115V 50A/230V

Leakage current

<3.5mA/240VAC

Overload protection

105%~150% Tpye:pulsing hiccup shutdown Reset: auto recovery

Over-voltage protection

5.75~6.75V

13.8~16.2V

18~21V

27.6~32.4V

57.6~67.2V

High-temperature protection

ERH1>=65 Fan on,<=55 Fan off,>70,Cut off output(5~15)

ERH1>=70 Fan on,<=65Fan off,>=80,Cut off output(24~48V)

Temperature coefficient

±0.03%/(0~50%)

Setup rise hold up time

200ms,100ms,20ms

Vibration

10~500Hz,2G 10min,/1cycle,Period for 60min,each axes

Withstand voltage

Input and output internal1.5KVAC,Input and enclosure1.5KVAC,Output and enclosure0.5KVAC

Isolation resistance

Input and output internal: Input and enclosure, Output and enclosure500VDC/100MΩ

Working temperature and humidity

-10~+60Refer to output derating curve,20%~90%RH

Store temperature and humidity

-20~+85,10%~95%RH

Overall dimension

215×115×50mm

Weight

1.2Kgs

Safety standards

Design refer to UL1950

EMC standards

Design refer FCC PART15 J Conduction class A

Note
1.The testing condition for the parameter above is :230VAC input, rated load,2570% RH.Humidity.
2. Error. Include the setting error, line stability and load stability. (Note: 5).
3.Wave test: adopting "A12"double wire for 20MHz, and 0.1UF&47UF capacitor short-circuit for interrupting.
4. Inlet voltage stability test: when is over load, the lowest voltage of inlet is up to the highest voltage.
5. Load stability test: the load is from 0% to 100%.