1.measure DC V, DC mV, resistance ,TC and RTD 2.Outputs resistance, simulation of TC and RTD 3.Automatic and manual cold end Basic Introduction  Function 

1) It allows you to measure DC V, DC mV, resistance ,TC and RTD.

2) Outputs resistance, simulation of TC and RTD.

3) Automatic and manual cold end temperature compensation for TC.

4) Manual stepping, automatic stepping, 0~100% phase step and ramp output.

5)Super-strong protection:The waterproof grade is IP67. Automatic protection against

the signal terminals connect to the 220V.

Summary of Source and Measure Functions 

Function

Measure

Source

DC V

0~30V

Not available

DC mV

0~120mV

0mV~100mV

Resistance

0~3200Ω

0~3200Ω

RTD

Pt100, Pt1000, Cu50, Cu100

Pt100, Pt1000, Cu50, Cu100

TC

E,J,K,T,B,R,S,N

E,J,K,T,B,R,S,N

Others

Stepping output, ramp, phase step output, user-defined range

Temperature Measurement

 1.Using Thermocouple (TC)

The calibrator supports eight standard thermocouples, including J, K, T, E, R, S, B, N.

 Lower table summarizes the ranges and characteristics of the supported thermocouples

Graduation

Positive lead material

Positive wire (H) color

Negative lead material

Specified span°C

ANSI*

IEC**

E

Chrome-nickel

Mauve

Purple

Constantan

-200~950

N

Nickel-chrome-silicon

Orange

Pink

Nickel-silicon-magnesium

-200~1300

J

Iron

White

Black

Constantan

-200~1200

K

Chrome-nickel

Yellow

Green

Alumel

-200~1370

T

Copper

Blue

Brown

Constantan

-200~400

B

Platinum (30% rhodium)

Grey

Platinum (6% rhodium)

600~1800

R

Platinum (13% rhodium)

Black

Orange

Platinum

-20~1750

S

Platinum (10% rhodium)

Black

Orange

Platinum

-20~1750

* Negative conductor (L) regulated as American National Standard (ANSI) is always red.

*Negative conductor (L) regulated as International Electro-technical Commission (L) is always white.

2.Using Resistance Thermometer Detector (RTD)

The calibrator accepts Pt100, Pt1000, Cu50 and Cu100, etc. The calibrator accepts RTD measurements inputs in two-, three-, or four-wire connections, with the three-wire connection the most common. A four-wire configuration provides the highest measurement precision, and two-wire provides the lowest measurement precision

Temperature Calibrator

Ads by Google


About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.