(120L,140L,160L,180L) Class B Vertical Pressure Steam Medical Autoclave Sterilization Machine
(120L,140L,160L,180L) Class B Vertical Pressure Steam Medical Autoclave Sterilization Machine

1.Medical Sterilizer manufacture 2.120L,140L,160L,180L, Vertical 3.LCD display, 3-6 times pulse vacuum 4.Iso:13485

Introduction:

MSG.B Class B Fully Automatic Vertical Pulse Vacuum Sterilizer is suitable for sterilizing unwrapped, wrapped, solid, hollow A, hollow B, instrument with built-in pipe and implanted instrument which can withstand high temperature and pressure in the places including oral department, ophthalmology, operation room and lab.

Technology advantage:

1.High quality plug-in microprocessor imported from America, the system is powerful and reliable.

2.Water filling, pulsing, heating up, sterilizing, drying process are fully automatic without artificial regulation.

3.Built-in high quality vacuum pulse (≥80L, high quality water-cycle pump used), vacuum pulse 3~6 times can reach -0.09 Mpa(-0.9Bar), to ensure effective removal of the air so as to get the optimum saturate steam.

4.Unique pulse vacuum drying procedure is designed, and the residue moisture shall be less than 0.2%.

5.Perfect fault warning system is designed, and fault messages are shown on LCD display real-timely.

6.Equipped with mini-printer is to restore sterilization cycle.

7.Cut-off electric protective function: Electricity is provided within 2 minutes and procedure continues to operate after cutting-off electricity.

8.Cycle count function.

9.The beep will sound once the sterilization cycle completes and messages are shown on LCD display at the same time.

Safety feature

Heater protection: the system will cut off its power supply once the temperature exceeds the desired value and show the alarm information.

Anti-dry heating: anti-dry heating device will automatically cut off its power supply and show the alarm information once the water level is lower than the heating pipe.

Safety interlock door (capacity ≤80L): Electric lock to ensure the sterilizer can begin to work only if the door is closed properly. The door can’t be opened when pressure is in chamber or the power supply is not connected.

Mechanical pressure interlock door (capacity ≥120L ): the mechanical door device is locked tightly and can’t be opened once pressure is in chamber.

Over-temperature and over-pressure protection: the system will start up procedures to lower temperature and release pressure to protect items from being damaged when the temperature and pressure in chamber exceed the safe limit.

Automatic release safety value: the safety value will begin to release pressure automatically when the pressure in chamber exceeds the desired value.

Electric safety protective measure: short circuit and leakage current are designed to protect equipment and personal safety.

Main parameter

Design pressure: 0.26MPa          

Design temperature: 150°C

Max. working pressure: 0.23MPa        

Sterilization temperature range: 105°C~136°C

Temperature accurate: 0.1°C        

Temperature homogeneity: ≤±0.5°C         

Chamber material: SUS304 stainless steel        

Water requirement: distilled water or pure water

Model

Chamber

Volume

Chamber dimensions

(Φ×L)

Outer dimensions(L×W×H)

Net weight

Power supply

Frequency

Power

MSG.B

120L

500×510mm

780×650×1550mm

252KG

380V

50HZ

7250W

MSG.B

140L

500×610mm

880×650×1550mm

275KG

380V

50HZ

7250W

MSG.B

160L

500×710mm

980×650×1550mm

290KG

380V

50HZ

7850W

MSG.B

180L

500×810mm

1070×650×1550mm

310KG

380V

50HZ

7850W