Welcome to ECBAY
New FlUKE 116C True-rms Multimeter DC/AC/ohm/F/Cap/Diod HVAC #6016
New FlUKE 116C True-rms Multimeter DC/AC/ohm/F/Cap/Diod HVAC #6016

Detailed Product Description


New FLUKE 116C True-RMS Digital MultiMeter

This Fluke 116C  newly released by Fluke China, is a battery-powered, true-rms multimeter with 6000-count display and a bar graph.New FLUKE 116C True-RMS Digital MultiMeter has AC/DC uAmps and temperature test function, used for HVAC professional, can help the specialist to discover the problem in heating, ventilates equipment, HVAC and flame detector. Fluke 116C has low impedance input (LoZTM) function as well as other functions. For example, testing warm and cold, ice control on heat pump as well as temperature investigation and so on.

Features:

  • White LED Backlight;

  • AC voltage: 0.100 V to 600 V ac rms (ac true-rms), frequency: 5 Hz to 50KHz;

  • DC voltage: 0.001 V to 600 V DC;

  • Measure resistance from  0.1 ohm to 40 M ohm;

  • Diode test and beeper warning;

  • Temperature range from -40C to 400C (-40F to 752F, including thermocouple)

  • Capacitor test from 1 nF to 9,999 uF;

  • Micro Amp measurement from 0.1uA to 600uA rms.

  • Frequency test from 5Hz to 50KHz

  • Low input impudence (LoZTM) help to prevent error reading due to noise voltage

  • Compact design for one-hand operation

  • three-year warranty from Fluke China.

 

General Specifications:

  • Maximum voltage between any terminal and earth ground .... ............... 600 V

  •  Surge Protection................... .......................................................... 6 kV peak per IEC 61010-1 600V CAT III, 

  • Pollution Degree 2 W Fuse for A input (115 & 117 only):....................... 11 A, 1000 V FAST 17 kA Fuse (Fluke PN 803293)

  • Display ............................................................................................ Digital: 6,000 counts, updates 4/sec Bar Graph: 33 segments, updates 32/sec 

  • Temperature .................................................................................... Operating: -10 °C to +50 °C Storage: -40 °C to +60 °C

  • Temperature Coefficient...................................................................... 0.1 x (specified accuracy)/°C (<18 °C or >28 °C)

  • Operating Altitude ............................................................................. 2,000 meters Battery ............................................................................................. 9 Volt Alkaline, NEDA 1604A / IEC 6LR61

  •  Battery Life .......................................................................................... Alkaline: 400 hours typical, without backlight 

  • Safety Compliances.............................................................................. Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 No 61010-1-04, UL 6101B (2003) and IEC/EN 61010-1 2nd Edition for measurement Category III, 600 V, Pollution Degree 2, EMC EN61326-1

  • Certifications.......................................................................................... UL, P, CSA, TÜV, ; (N10140), VDE

 

Ads by Google


About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.