Fluke F115 115C Field Multimeter 1000uF Backlight #6015
Detailed Product Description
Details
- Large white LED backlight to work in poorly lit areas
- Resistance and continuity
- Min/Max/Average to record signal fluctuations
- CAT III 600 V safety rated
Specifications |
Maximum voltage between any terminal and earth ground | 600 V |
Surge protection | 6 kV peak per IEC 61010-1 600 VCAT III, Pollution Degree 2 |
Display | Digital: 6,000 counts, updates 4 per second |
Bar graph | 33 segments, updates 32 per second |
Operating Temperature | -10 °C to + 50 °C |
Storage Temperature | -40 °C to + 60 °C |
Battery type | 9 volt Alkaline, NEDA 1604A/ IEC 6LR61 |
Battery Life | 400 hours typical, without backlight |
Accuracy Specifications |
DC millivolts | Range: | 600.0 mV | Resolution: | 0.1 mV | Accuracy: | ± ([% of reading] + [counts]): 0.5% + 2 |
|
DC volts | Range/Resolution: | 6.000 V / 0.001 V | Range/Resolution: | 60.00 V / 0.01 V | Range/Resolution: | 600.00 V / 0.1 V | Accuracy: | ± ([% of reading] + [counts]): 0.5% + 2 |
|
AC millivolts1 true-rms | Range: | 600.0 mV | Resolution: | 0.1 mV | Accuracy: | 1.0 % + 3 (dc, 45 Hz to 500 Hz)2.0 % + 3 (500 Hz to 1 kHz) |
|
AC volts1 true-rms | Range/Resolution: | 6.000 V / 0.001 V | Range/Resolution: | 60.00 V / 0.01 V | Range/Resolution: | 600.0 V / 0.1 V | Accuracy: | 1.0 % + 3 (dc, 45 Hz to 500 Hz)2.0 % + 3 (500 Hz to 1 kHz) |
|
Continuity | Range: | 600 Ω | Resolution: | 1 Ω | Accuracy: | Beeper on < 20 Ω, off > 250 Ω; detectsopens or shorts of 500 μs or longer. |
|
Ohms | Range/Resolution: | 600.0 Ω / 0.1 Ω | Range/Resolution: | 6.000 kΩ / 0.001 kΩ | Range/Resolution: | 60.00 kΩ / 0.01 kΩ | Range/Resolution: | 600.0 kΩ / 0.1 kΩ | Range/Resolution: | 6.000 MΩ / 0.001 MΩ | Accuracy: | 0.9 % + 1 | Range/Resolution: | 40.00 MΩ / 0.01 MΩ | Accuracy: | 5 % + 2 |
|
Diode Test | Range/Resolution: | 2.00 V / 0.001 V | Accuracy: | 0.9% + 2 |
|
Capacitance | Range/Resolution: | 1000 nF / 1 nF | Range/Resolution: | 10.00 µF / 0.01 µF | Range/Resolution: | 100.0 µF / 0.1 µF | Range/Resolution: | 9999 µF / 1 µF | Range/Resolution: | 100 µF to 1000 µF | Accuracy: | 1.9% + 2 | Range/Resolution: | > 1000 µF | Accuracy: | 5% + 20% |
|
Lo-Z Capacitance | Range: | 1 nF to 500 µF | Accuracy: | 10% + 2 typical |
|
AC amps true-rms (45 Hz to 500Hz) | Range/Resolution: | 6.000 A / 0.001 A | Range/Resolution: | 10.00 A / 0.01 A | Accuracy: | 1.5% + 3 | | 20 A overload for 30-seconds max |
|
DC amps | Range/Resolution: | 6.000 A / 0.001 A | Range/Resolution: | 10.00 A / 0.01 A | Accuracy: | 1.0% + 3 | | 20 A overload for 30-seconds max |
|
Hz (V or A input)2 | Range/Resolution: | 99.99 Hz / 0.01 Hz | Range/Resolution: | 999.9 Hz / 0.01 Hz | Range/Resolution: | 9.999 kHz / 0.001 kHz | Range/Resolution: | 50 kHz / 0.01 kHz | Accuracy: | 0.1% + 2 |
|
Notes:
- All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V.
- Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
- Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.
- Temperature Range/Resolution: -40 °F to 752 °F / 0.2 °F
- Frequency is ac coupled, 5Hz to 30 kHz for ac voltage
Mechanical & General Specifications |
Size | 167 x 84 x 46 mm (6.57" x 3.31" x 1.82") |
Weight | 550 g |
Including:
- 1 X F115C
- 1 X pair of leads
- 1X manual