Welcome to ECBAY
Low ambient temperature EVI air to water(air source) heat pump three-purpose unit(HVAC central air conditioner 12kW 15kW )
Low ambient temperature EVI air to water(air source) heat pump three-purpose unit(HVAC central air conditioner 12kW 15kW )

Apply to sanitary hot water,heating,cooling EVI compressor Heating normally in -25deg C Five modes Electronic expansion valv

Product Features:1.Applied range:heating,cooling,sanitary hot water.2.Enhanced vapor injection compressor.3.Five modes:   Hot water;Heating;Cooling;Heating + Hot water;Cooling + Hot water.4.On the Heating+hot water or cooling+hot water model,priority to hot water.5.Eco-friendly refrigerant: R407C.6.Electronic expansion valve regulates the flow of refrigerant precisely.7.Air exchanger(Fins-coil) with hydrophilic coating.8.Galvanized plate shell, powder coating.9.LCD display wire controller.10.Can set the operating time freely. 11.Unit runs or stop automatically according to water  temperature.12.Compatibility of indoor signal control(10~12V).13.Water flow protection control.14.Can control the auxiliary heating (e.g. electric heating).15.With hot water return control, to keep the water warm in supplying pipe.16.Water flow protection control.17.Automatic prevent freezing in the winter.18.Automatic defrosting.19.Failure diagnosing function.

Specifications:

ModelKFRS-18J2LDPAKFRS-22J2LDP
Power supply(V/Ph/Hz)380-415/3/50
Hot water modeHeating capacitykW1822
Rated power inputkW4.24.9
COPW/W4.34.5
Hot water outputL/h390480
Hot water temp.°C20~60
Floor heating modeHeating capacitykW1518.5
Rated power inputkW3.84.7
COPW/W3.93.9
Fan coil heatingHeating capacitykW15.018.5
Rated power inputkW4.455.50
COPW/W3.43.4
CoolingCooling capacitykW1215
Rated power inputkW4.205.20
EERW/W2.92.9
Water flowm3/h3.44.1
Water resistancekPa≤10≤15
Compressor type EVI Scroll
Refrigerant R407C
Noise   dB(A)5859
Net weightkg124154
Unit dimensions(L×W×H)mm755×755×980
Packing dimensions(L×W×H)mm780×780×1020
Stacking layerslayer22
Water pipe connectormmDN25(1")DN25(1")
Ambient condition°C-25~43
Water side exchanger PHE
Water flow switch accessoryaccessory
1)Hot water rated test conditions: Ambient temp.(DB/WB): 20°C/15°C,Initial water temp. 15°C,temp. rise 40°C.2)Floor heatling rated test conditions:Ambient temp.(DB/WB): 7°C/6°C,Water temp.(In/Out):30°C/35°C.
Remarks:Flexible range with other various power supply available according to the client's requirement.

Low ambient temperature EVI air to water(air source) heat pump three-purpose unit(HVAC central air conditioner 12kW 15kW )

Ads by Google


About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.