Welcome to ECBAY
Low ambient temperature EVI air to water heat pump heating and cooling unit(HVAC central air conditioner 8kW 10kW 12kW)
Low ambient temperature EVI air to water heat pump heating and cooling unit(HVAC central air conditioner 8kW 10kW 12kW)

Apply to residential or commercial heating and cooling EVI compressor Heating normally in - 25deg C Soft start

Product Features:1.Applied range: residential and commercial heating,cooling.2.Enhanced vapor injection compressor.3.Heating operate normally in - 20°C,and hot water 50°C.4.Eco-friendly refrigerant: R407C.5.Expansion valve regulates the flow of refrigerant precisely.6.Heat-exchanger cycle technology to further improve operation under low ambient temperature.7.Air exchanger(Fins-coil) with hydrophilic coating.8.LCD display wire controller.9.Can set the operating time freely. 10.Unit runs or stop automatically according to water return temperature.11.Compatibility of indoor signal control(10~12V).12.Can control the auxiliary heating (e.g. electric heating).13.Water flow protection control.14.Automatic prevent freezing function in the winter.15.Automatic defrosting.16.Failure diagnosing function.

Specifications:

ModelKLRS-8J1PKLRS-10J1PKLRS-12J2P
Power supply(V/Ph/Hz)220-240/1/50380-415/3/50
Floor heatingHeating capacitykW9.512.515
Rated power inputkW2.453.13.8
COPW/W3.94.03.9
Fan coil heatingHeating capacitykW9.512.515.0
Rated power inputkW2.803.704.45
COPW/W3.43.43.4
CoolingCooling capacitykW81012
Rated power inputkW2.753.304.20
EERW/W2.92.92.9
   2.93.02.9
Circulating water flowHeatingm3/h1.82.32.8
Coolingm3/h1.51.92.3
Water resistancekPa≤10
Compressor type EVI Scroll
Refrigerant R407C
Noise   dB(A)585858
Net weightkg102130130
Unit dimensions(L×W×H)mm960×340×1260
Packing dimensions(L×W×H)mm1100×480×1350
Stacking layerslayer111
Water pipe connectormmDN25(1")DN25(1")DN25(1")
Ambient condition°C-20~60
Water side exchanger PHEPHEPHE
Water flow switch accessoryaccessoryaccessory
1)Floor heating rated test conditions:Ambient temp.(DB/WB): 7°C/6°C,Water temp.(In/Out):30°C/35°C.2)Fan coil heating rated test conditions:Ambient temp.(DB/WB): 7°C/6°C,Water temp.(In/Out):40°C/45°C.3)Cooling rated test conditions:Ambient temp.(DB/WB): 35°C/24°C,Water temp.(In/Out):12°C/7°C.
Remarks:Fexible range with other refrigerants (e.g. R22), other various power supply available according to the client's requirement.

Low ambient temperature EVI air to water heat pump heating and cooling unit(HVAC central air conditioner 8kW 10kW 12kW)

Ads by Google