Technical Specifications

1. The Power Source and the Voltage:     AC220V±5%, 50-60 Hz

Time-delayed control:                2-60 seconds, adjustableThe Max. Height of the Testing Specimen:          175 mmThe Distance from the Indenter Center to the Instrument Body:    165mm.Overall Dimension (Length×Width×Height):    551×260×800 mmThe Net Weight of the Tester:                    80kg (Approx).

Rockwell Hardness

7. The Technical Specifications of Rockwell Hardness

Rockwell Hardness

Test Force

Initial Test Force(N)

98.07(10kg)

Tolerance±2.0%

Total Test Force(N)

588.4(60 kg)

Tolerance±1.0%

980.7(100 kg)

1471(150kg)

Indenter

Diamond Cone Indenter

Diameter 1.5875mm Ball Indenter

Scale

HRA

HRB

HRC

HRD

HRE

HRF

HRG

HRH

HRR

HRM

HRP

HRS

HRK

HRL

HRV

        

8. The allowed tolerances of the Rockwell hardness displaying values

Scales

Hardness Range of the Standard Hardness Blocks

Allowed Tolerance of Displaying Value

Allowed Repeatability of Displaying Value a

A

(20~≤75)HRA

±2HRA

≤0.02(100-H)

or 0.8 Rockwell unit b

(>75~≤88) HRA

±1.5HRA

B

(20~≤)45HRB

±4HRB

≤0.04(130-H)

or 1.2 Rockwell unit b

(>45~≤80)HRB

±3HRB

(>80~≤100)HRB

±2HRB

C

(20~≤70)HRC

±1.5HRC

≤0.02(100-H)

or 0.8 Rockwell unit b

a:H means average hardness value       b:select a larger value

Superficial Rockwell hardness

9. The technical specifications of superficial Rockwell hardness

Superficial Rockwell

Test Force

29.42(3 kg)

Allowed Tolerance±2.0%

147.1(15 kg)

Allowed Tolerance±1.0%

294.2(30 kg)

441.3(45 kg)

Indenter

Diamond Cone Indenter

Diameter 1.5875mm Ball Indenter

Scales

HR15N, HR30N , HR45N

HR15T, HR30T , HR45T

HR15W, HR30W, HR45W

HR15X, HR30X, HR45X

HR15Y, HR30Y, HR45Y

10. The repeatability of the superficial Rockwell hardness displaying values and allowed tolerance of displaying value

Scales

Hardness Range of the Standard Hardness Blocks

Allowed Tolerance of Displaying Value

Allowed Repeatability of Displaying Value a

15N

(0~77)HR 15N

±2 HRN

≤0.04(100-H)or

1.2 Rockwell unit b

(78~88)HR 15N

(89~91)HR 15N

30N

(42~54)HR 30N

(55~73)HR 30N

(74~80)HR 30N

45N

(20~31)HR 45N

(32~61)HR 45N

(63~70)HR 45N

15T

(73~80)HR 15T

±3 HRT

≤0.06(100-H)or

2.4 Rockwell Unit b

(81~87)HR 15T

(88~93)HR 15T

30T

(43~56)HR30T

(57~69)HR 30T

(70~82)HR 30T

45T

(12~33)HR 45T

(34~54)HR 45T

(55~72)HR 45T

a:H means average hardness value

b:select a larger value

CE certified,SCTMC Digital Double Rockwell Hardness Tester

Ads by Google


About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.