1.easy to operate. 2.fast and intuitive interface. 3.basically, no human operation error. 4.high sensitivity, stability
Technical specifications
1. The Power Source and the Voltage: AC220V±5%, 50-60 Hz
Time-delayed control: 0-60 seconds, adjustableThe Distance from the Indenter Center to the Instrument Body: 165mmOverall Dimension (Length×Width×Height): 551×260×800 mmThe Net Weight of the Tester: 80kg (Approx)Rockwell Hardness
6.Specifications of Rockwell Hardness
Testing force(N) | Initial Testing Force | 98.07(10kg) | Tolerance ±2.0% | |
Total testing force | 588.4(60kg) | Tolerance ±1.0% | ||
980.7(100kg) | ||||
1471(150kg) | ||||
Indenter | Diamond Cone Indenter | |||
diameter 1.5875mm Ball Indenter | ||||
Scales | HRA | HRB | HRC | HRD |
Max height of samples | 175mm | |||
7. The Tolerance of Rockwell Hardness Display Value
Hardness Scale | Hardness Range of The Standard Testing Blocks | The Max. Tolerance of Display Value | Repeatability a |
HRA | (20~≤75)HRA | ±2HRA | ≤0.02(100-H)or 0.8 Rockwell Unit b |
(>75~≤88)HRA | ±1.5HRA | ||
HRB | (20~≤45)HRB | ±4HRB | ≤0.04(130-H)or 1.2 Rockwell Unit b |
(>45~≤80)HRB | ±3HRB | ||
(>80~≤100)HRB | ±2HRB | ||
HRC | (20~≤70)HRC | ±1.5HRC | ≤0.02(100-H)or 0.8 Rockwell Unit b |
a:H is average hardness value b:Confirm as higher value |
Brinell Hardness
8. The Technical Specification of Brinell Hardness Tester
Testing force | 294.2N(30kg) | Tolerance ±1.0% | ||
306.5N(31.25kg) | ||||
612.9N(62.5kg) | ||||
980.7N(100kg) | ||||
1839N(187.5kg) | ||||
Indenter | φ2.5mm,φ5mm Ball Indenter | |||
Scales | HBW1/30 | HBW2.5/31.25 | HBW2.5/62.5 | |
HBW5/62.5 | HBW10/100 | HBW2.5/187.5 | ||
Eyepiece magnification | 15× | |||
Objective | 2.5×(resolution 0.5μm),5×(resolution 0.25μm) | |||
Max Height of Sample | For 2.5×:Max Height is 95mm For 5×:Max height is 115mm | |||
9. The Tolerance and Repetition of Displayed Value for Brinell Hardness Tester
Hardness Block(HBW) | Tolerance(%) | Repeatability (%) |
≤125 | ±3 | 3 |
125<HBW≤125 | ±2.5 | 2.5 |
>225 | ±2 | 2 |
Vickers Hardness
10. Technical Specifications of Vickers Hardness
Test force | 294.2N(30kg) | Tolerance ±1.0% |
980.7N(100kg) | ||
Indenter | Diamond Vickers Indenter | |
Scale | HV30 | HV100 |
Eyepiece magnification | 15× | |
Objective magnification | 5×(Resolution 0.25μm) | |
Max. Height of Specimen | 115mm |
11. The Tolerance and Repetition of Displayed Value for Vickers Hardness Tester
Tolerance of Displayed Value | Repetition of Displayed Value | |||
Hardness scale | Value of Hardness Block | Tolerance of Displayed Value | Value of Hardness Block | Repetition of Displayed Value |
HV30 HV100 | ≤250HV | ±3% | ≤225HV | 6% |
300~1000HV | ±2% | >225HV | 4% |
CE certified, SCTMC Universal Digital Multi-functional Hardness Tester
Verified Information This information is Verified by Bureau Veritas and validity period is 2012/10/10 --- 2013/10/10 All the information below may covers both Gold Supplier and its related companies , Their Relationship will be affirmed according to china laws and regulations , also it will be clearly display in the full report >> Production Capacity:Testermachine | 2,000 sets per year | confidential |
North America | confidential | 6.6 |
South America | confidential | 4.45 |
Eastern Europe | confidential | 5.0 |
Southeast Asia | confidential | 4.0 |
Africa | confidential | 1.8 |
Oceania | confidential | 1.85 |
Mid East | confidential | 2.15 |
Eastern Asia | confidential | 3.3 |
Western Europe | confidential | 3.5 |
Central America | confidential | 1.35 |
Northern Europe | confidential | 2.95 |
Southern Europe | confidential | 2.9 |
South Asia | confidential | 2.4 |
Domestic Market | confidential | 57.75 |
Digital control lathe | GSK980TDb | 4 | 3.0 | Acceptable |
Machining center | B-64304CM/01 | 2 | 3.0 | Acceptable |
Horizontal lathe | C6232A1 | 6 | 6.0 | Acceptable |
Super CNC wire cutting machine | D10732 | 4 | 4.0 | Acceptable |
Surface grinding machine in horizontal | M7130 | 2 | 4.0 | Acceptable |
Horizontal boring machine | TX68 | 6 | 6.0 | Acceptable |
Universal knee-and-column milling machine | X6132A | 2 | 2.0 | Acceptable |
Universal miller | 57-3C | 5 | 2.0 | Acceptable |
Shaper | B6050 | 2 | 4.0 | Acceptable |
Vertical honing machine | M4215 | 1 | 3.0 | Acceptable |
Digital voltmeter | Victor 9806 | 2 | 2.0 | Acceptable |
Tensile testing machine | R-18905-B | 1 | 4.0 | Acceptable |
Environment chambers | VC7033 | 1 | 4.0 | Acceptable |
Dynamometer | XK3190-A1 | 4 | 2.0 | Acceptable |
ISO 9001:2008 | Beijing Zhongdahuayuan Certification Center, ANAB | ANAB12Q20049R0M | Scope: Design, research and production of hardness testers; manufacture for metallurgical equipments | 2012/01/18 --- 2015/01/17 | |
CE | QS | 7602 | Hardness tester, XHB-3000, MHB-3000, DHB-3000, DTLC-3000, HVS-5, HVS-10, HVS-30, HVS-50, HVS-5P, HVS-10P, HVS-30P, HVS-50P, HVS-5Z, HVS-10Z, HVS-30Z, HVS-50Z, HV-1000, 402SXV, XHV-1000Z, MHV-2000, MHV-2000Z, HVS-1000, HVS-1000Z, DHV-1000, DHV-1000Z, HRS-150, HR-150DT, HR-150A, HRMS-45, HRM-45DT, HRM-45, 560RSS, 570-HAD, 601MHB, XHR-150, HBRV-187.5, XHRS-150, HRX-150, MHV-5Z, MHV-10Z, MHV-30Z, MHV-50Z | 2011/12/05 --- 2049/12/31 |
Verification Certificate | SIMT | Digital brinell hardness tester, XHB-3000 | 2012/03/28 |