Detailed Product Description


     

      The new generation of AEC2232dX series of combustible gas detector can detect environmental scene shows in the combustible gas explosion limit within or steam concentration (% LEL), and 4 ~ 20mA output signal output and standard three group relay contacts signal (fault signal, the upper limit alarm signal, the lower limit alarm signal), direct access DCS/RTU/EDS/PLC etc data acquisition system or other secondary instrument sound-light alarm output, and linkage to avoid malignant accidents.

     This series still has the following characteristics: to probe the highlighted LED display, Low/upper limit alarm concentration can be set, Using button, can according to demarcate calibration gases concentration calibration value set, The site also optional iron calibration, calibration shall not open, when the operation more convenient.

     This series of detector using catalytic combustion sensor and digital processing technology. Products with high sensitivity, stability testing, toxic, low consumption, etc.

      This series of detectors are widely used in petroleum, chemical, pharmaceutical, steel, special industrial workshop etc, and other existing combustible gas or flammable vapors.

 

·         Well-known brand sensor, high accuracy, good stability and resistance to poisoning ability, low consumption, High-performance micro controller processing technology, auto fault recognition, automatic alarm.

·         Highlight LED scene shows, low/upper limit alarm concentration field setting.

·         Buttons, simple and convenient; calibration Iron calibration, no open operation.

·         4 ~ 20mA standard signal and three group relay contacts output can be fit for linkage of control system and the output control equipment.

 

·         Detect principle:

Catalytic combustion

·         Detected gas

Combustible gas

·         Range

0-100LEL

·         Accuracy:

±5%F.S

·         Power supply:

DC24V±6V

·         Power consumption:

≤3W

·         Operating environment:

-40-+70; Relative Humidity≤93%incondensable

·         Output: 

4 - 20mA standard signal and three group relay contacts output

·         Display:

LED

·         Installation:

Hanging, suck, holding tube

·         Explosion proof connection thread:

G3/4internal

·         Explosion-proof Class:

ExdCT6

·         Protection Class:

Up to IP66

·         Material:

Aluminum