The product is applicable to transformers, generators, motors, and other electrical equipment reactor windings.
Performance Features:
Enameled aluminum wire ,High resistance to heat shock, high temperature and good performace at softening breakdown, suitable for highspeed automated routing, able to be direct weld, with no pinhole, resistive to high frequency, wearing, refrigerants and electronics corona, high breakdown voltage
Production range:
Executive standard: GB/T7095-2008
a:thickness of conductor is 0.90~5.00mm ,
b:width of conductor is 3.00~16.00mm
width-to-thickness ratio is 1.5<b/a<7.5
Product details:
1. 180 polyester-imide enamelled copper flat wire (aluminum)
2. 200 grade polyester / polyamide imide compound enameled copper flat wire (aluminum)
3. 120 (155) acetal enameled copper flat wire (aluminum)
4. 120 stage thermal adhesive polyvinyl acetal enamelled copper flat wire (aluminum)
5. 155 polyester enamelled copper flat wire (aluminum)
Product introduction:
Enamelled rectangular wires is insulating paint which in the oxygen-free copper rod or electrical round aluminum rod by a variety of mold drawing wire, according to customer requirements, with the desired temperature index and compatibility of insulating paint, using a mold or felt type painting, coating the multi-channel corresponding insulation paint, so that the insulating paint and conducting wires to form a whole after baking.
Paint-Film thickness:
if have special requirements with the paint-film thickness, please contact us.
OUR FACTORY
Enameled Copper/Aluminum wire
Verified Information This information is Verified by Bureau Veritas and validity period is 2012/05/17 --- 2013/05/17 All the information below may covers both Gold Supplier and its related companies , Their Relationship will be affirmed according to china laws and regulations , also it will be clearly display in the full report >> Production Capacity:Cable and Wire | 490,000km | 437,518km |
Southeast Asia | USD 775,588 | 0.27 |
Africa | USD 54,885 | 0.02 |
Domestic Market | USD 283,335,769 | 99.71 |
Drawing Machine | Shunde Yongxiong, BT22-2 | 14 | 9.0 | Acceptable |
Drawing Machine | Heifei Huaxin, LHD-450/13 | 1 | 12.0 | Acceptable |
Drawing Machine | Shunde yongxiong, ZL250 | 2 | 6.0 | Acceptable |
Frame-Type Strander | Heifei Shenma, JLK-500 6+12+18 | 1 | 3.0 | Acceptable |
1+3 Cable-Former | Shanghai Diangong, JCLL+3/1600 | 1 | 26.0 | Acceptable |
Wire Extruding Machine | Dongguan Jingite, FAI90 | 1 | 3.0 | Acceptable |
Spark Test Machine | Shanghai Lanbo, AWSC-35 60 | 4 | 3.0 | Acceptable |
35KV Cables Cross-Link | Qingdao Woke, 35KV | 1 | 1.0 | Acceptable |
110KV Cables Cross-Link | COLTD, 110KV-CCV-Line)- | 1 | 7.0 | Acceptable |
Metal Shield Machine | Xiangtan Dayangxiangfeng, KRT 630 | 1 | 15.0 | Acceptable |
DC Resistance Measurement Instrument | Shanghai Taiou, PC36C | 1 | 3.0 | Acceptable |
Tension Tester | XLL-500 | 1 | 30.0 | Acceptable |
Electronic balance | Jiangsu Tianrui, EDX1800 | 1 | 2.5 | Acceptable |
Semiconducting Rubber resistance Measurement Instrument | DB-4 | 1 | 10.0 | Acceptable |
Dispersive X-ray Fluorescence Spectrometer | Jiangsu Tianrui, EDX1800 | 1 | 2.5 | Acceptable |
Hygrothermograph | Shanghai Huacheng | 1 | 2.0 | Acceptable |
Shielding lab. For Partial Discharging | Shanghai Lanbo | 1 | 6.0 | Acceptable |
110KV Partial Discharging Test System | HIGHVOLT, SIN305/0315 | 1 | 6.0 | Acceptable |
Certificate of Approval for Fire Resistance | National Supervising Test Centre for Fire Protection of Building Material Quality | Fcz2010079 | Low - Smoke, Halogen-Free Control Cable, WDZAN - KYJY - 450/750V | 2010/06/11 --- 2013/06/10 | |
Certificate of Approval for Fire Resistance | National Supervising Test Centre for Fire Protection of Building Material Quality | Fcz2010078 | Copper Core, XLPE Insulated, PVC Sheathed, Low-Smoke, Halogen-Free, Power Cable with Concentric Conductor WDZAN - YJY(T) - 0.6/1.0kV | 2010/06/11 --- 2013/06/10 | |
Certificate of Approval for Fire Resistance | National Supervising Test Centre for Fire Protection of Building Material Quality | Fc200950554 | WDZC - BYJ - 450/750V | 2009/11/06 --- 2012/11/05 | |
Certificate of Conformity RoHS | China Quality Certification Centre | CQC11130060964 | Lead-free Copper Polyvinyl Chloride Insulated Environmental Cable and Wires of Rated Voltages up to and including 450/750V | 2012/08/01 --- 2012/08/01 |
China Compulsory Certification | National Center for Quality Supervision & Test of Electric Wire and Cable | Cable for Railway Vehicle, WDZ - DCYJB/3 - 125 | 2012/02/16 | |
Test Report | National Center for Quality Supervision & Test of Electric Wire and Cable | Cu-Core, Low-Smoke, Halogen-Free, Flameproof Class A, Termite/Rat, Resistance, PVC Sh eathed, Copper Tape Screened Cable, WDZA - YJY63 26/35kV | 2012/02/20 | |
Test Report | China National Supervision and Test Center for Cable and Wire Production Quality (Wuhan) | per-Cored, XLPE Insulated, Creasing - Aluminum Sheathed and PVC Sheathed Power Cable, WDZA - FSY - YJY63 | 2012/02/20 |