Welcome to ECBAY
SRUF160B MEMBRANE MODULE ,HOLLOW FIBER UF MEMBRANE FOR WATER TREATMENT
SRUF160B MEMBRANE MODULE ,HOLLOW FIBER UF MEMBRANE FOR WATER TREATMENT

Membrane module SRUF-160B -UF technology is efficient,environmentally,energy-saving separtation process -Water flux is large

Hollow-fiber Ultrafiltration Membrane Module SRUF-160B

 

The characteristics of Ultrafiltration technology:

-UF tech. is an efficient and environmentally,energy-saving separation process

-Using lower pressure as a driving force

-UF separation process is on under room temperature,low energy consumption

-The scale and handle ability range of UF process is large

 

 

More info. pls visit to our website: www.suoai.en.alibaba.com

Any question pls feel free to contact us(Trade Manager is cn220180523)

 

Suoai Membrane Fairy: SRUF-160B

1.PERFORMANCE PARAMETERS

Membrane material

Polyvinyl Chloride(PVC)

Molecular Weight Cut-off(MWCO)

80.000-10.000 Dalton

Inner and outer diameters of hollow-fiber

0.9mm/1.6mm

Membrane fiber type

Inside-out hollow-fiber

Charateristics of membrane structure

Hydrophilic double-compact layers

Dimensions of membrane module

160*1414mm

Area of membrane module

17m2

Pure water flux

4000L/H

2.APPLICATION CONDITIONS

Pre-filtration

50-150um

Max. turbidity of inlet water

<=15NTU

 Rate flux

60-160L/M/H 

Running mode

Cross-flow filtration or dead end filtration 

 Max.inlet water pressure

0.45MPa 

Pressure difference of transmembrane at 20°c(TMP)

 28-150KPa

Max.Pressure difference of transmembrane 

 0.2MPa

 

 Applicable PH range

 2-12

 Applicable temperature

 5°c

 Tolerable continuous residual chlorine

 100PPm

 

 

 Tolerable interval residual chlorine

 200PPm

3.BACKWASHING DESIGN

Backwashing pressure

0.25MPa

Backwashing flow

220-300L/M/H

Backwashing frequency

Every20-60 minutes

Backwashing time

30-60 seconds every time

Frequency of chemically enhanced backwashing(CEB)

Auto adding of additives in backwashing is recommended

Time of chemically enhanced backwashing(CEB)

30-60seconds every time

4.CHEMICALLY WASHING DESIGN

Frequency of chemically washing

every1-4months or when TMP is over0.15MPa

Pressure of chemically washing

0.15Mpa

Flow of chemically washing

200-250L/M/H

Time of chemically washing

60-90 minutees every time

Acid washing chemical

Citric acid or oxalic acid(mixed into solution with PH=2)

 Alkali washing chemical

NaoH (mixed into solution with PH=2)

 5.INDEX OF OUTPUT WATER

Turbidity of output water

<0.1NTU

Index of silt density

<1.5

Remarks:

1.Pure water flux is measured with pure water at25°c with inlet water pressure of 0.1MPa.

2.If water sources are from surface water,river water or well water and so on,pre-treatment shall be done.

It is suggested that a 50-150um precision filter shall be equipped to have inlet water with turbidity<=15NTU.

 Microorganism,pathogen

99.9%Removed 

 

SRUF160B MEMBRANE MODULE ,HOLLOW FIBER UF MEMBRANE FOR WATER TREATMENT

Ads by Google


About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.