Specifications:
1) Analogue output 8 types of thermocouple
2) 2 types of thermo-resistance
3) DCV output and resistance analogue output
4) MV and resistance output function can take the calibration of process
calibration of extra temperature
5) Celsius scale/Fahrenheit scale displaying
6) 5-digits LCD easy keyboard operation
7) Auto calibrate function
8) Small, suitable for field operation
9) Color: dark gray
10) Size: 20 x 100 x 40mm

Output Range Output range Resolution Accuracy Expalnation
Voltage100mV-10.00 ~110.00mV0.01mV±0.05% Setting value ±30uVThe max. output current ±5mA
1000mV-100.00~1100.0mV0.1mV±0.05% Setting value ± 0.3mV
Resistance400Ω0.0~400.0Ω0.1Ω±0.05% Setting value ±0.2Ω1mA exciting current (note1.2)
ThermocoupleR-40~17601±0.05% Setting value ±3 (≤100)Adopt the ITS-90
S-20~17601±0.05% Setting value ±2(100)
B400~18001±0.05% Setting value ±3 (400~600)temperature standard
±0.05% Setting value ±2 (600)
E-200.0~1000.00.1±0.05% Setting value ±2 (≤-100)(Note 3)
K-200.0~13700.1
J-200.0~1200.00.1±0.05% Setting value ±1(-100)
T-200.0~400.00.1
N-200.0~1300.00.1
Thermo-resistancePt100-200.0~850.00.1±0.05% Setting value ±0.6Adopt the PT100-385 1mA
(Note 1.2)
Cu50-50.0~150.00.1



Inner packing: