Welcome to ECBAY
true on line double convertion three phase in three phase out 15KVA UPS
true on line double convertion three phase in three phase out 15KVA UPS

1. Three phase in and out system, compatible with utility of 380/400/415V, 50/60Hz 2.Online double conversion,

Capacity

6KVA

12KVA

18KVA

Main Input

Input voltage

200V/208V (line to line), 50/60Hz

Input connection

3Ph+N+PE

Power factor

>0.99

Input voltage window

+20%~-20%, full load

-20%~-40%, power derating between 100% to 70%

Frequency window

40-70HZ

Bypass input

Bypass voltage

200V/208V

Bypass voltage window

+15%--20%, full load

Frequency window

±5Hz

Battery

Battery voltage

±120VDC

Charger power

20%*Power

Charger voltage precision

1%

Output

Voltage precision

±1% (balance load),2% (unbalance load)

Output voltage transient

5%(0~100% load step)

Voltage THD(Total Harmonic Distortion)

THD<2%(linear load),THD<5%(nonlinear load)

Power factor

0.8

Frequency tracking range

50/60Hz±3Hz, adjustable

Frequency precision (free running)

±0.02%

Phase tolerance

120°±0.5° (balance and unalance load)

Voltage unbalance degree (100% unbalance load)

±2%

Frequency tracking speed

0.5Hz/s to 5Hz/s, adjustable

Crest factor

3:1

Overload capabiltiy

102% long time operation

110%, transfer to bypass after 1hour

125%, transfer to bypass after 10 minutes

150%, transfer to bypass after 1 minute

>150%, transfer to bypass after 200ms

Bypass overload capability

125%, long time operation

125%< load <130%, last for more than 1 hour

130%<load<150%,last for more than 6 minutes

>1000%, last for more than 100ms

System

System efficiency

Normal mode: 90%

ECO mode: 99%

Battery mode efficiency

90%

Battery configuration

12V, 20PCS 

Display

LCD+LED, keyboard

EMI

IEC62040-2

EMS

IEC61000-4-2(ESD)

IEC61000-4-3(RS)

IEC61000-4-4 (EFT)

IEC61000-4-5 (Surge)

Insulation resistance

>2M (500VDC)

Dielectric strengh

(input,output to PE)2820Vdc, leakage current lower than 3.5mA, no flashover in 1 minute

Surge protection

Comply with IEC60664-1 class IV, endure surge of 1.2/50us + 8/20us higher than 6KV/3KA

IP class

IP20

Interface (Communication Ports )

RS232,RS485,Dry contacts,SNMP card,EPO,Generator interface

Installation/Connection

Top or bottom cable connection

Operation temperature

0-40°C

Relative humidity

0-90% (non-comdensing)

Noise(dB)

<55dB

Weight(KG)

68

68

78

Dimension(W*D*H)(mm)

520*700*1100(Internal battery)

please contact linda for price skype: lindayunyun

true on line double convertion three phase in three phase out 15KVA UPS

Ads by Google


About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.