PCS Line-Interactive UPS
Yueqing Open Imp.&Exp. Co., Ltd. [China]
1CPU control 2Wide Input Voltage Range 3High/Low Voltage Protection, Overload/Short Protection Specifications
wide input voltage range 145-290v micro process control LCD LED optional USB, RS232,RJ45 optional with voltage regulator
1CPU control 2Wide Input Voltage Range 3High/Low Voltage Protection, Overload/Short Protection 4Cool start computer even there is not main power 5Automatic recharge even UPS is off 6Automatic restart 7Beeping Alarm on Battery, Battery Low and Overload 8Beeping Selection 9Intelligent Battery Management
Product | Requirements | Model 1 | Model 2 | Model 3 | Model 4 | Model 5 |
Power (VA) | PCS-500 | PCS-650 | PCS-800 | PCS-1000 | PCS-1500 | |
Input | Voltage | 145-290VAC±5V | ||||
Frequency | 50Hz+/-10% | |||||
Output | Voltage (AC Mode) | 190-250VAC | ||||
Voltage (Inverter Mode) | 220VAC ±5% | |||||
Capacity | 500VA/300W | 650VA/360W | 800VA/480W | 1000VA/600W | 1500VA/880W | |
Frequency (Inverter Mode) | 50Hz+/-0.5Hz | |||||
Transfer Time | 4ms typical | |||||
Generator connection | Normal Working under the Generator | |||||
Waveform | modified-Sinewave | |||||
Protection | Spike & Surge Suppression | yes | ||||
Over/Under Volt. | Switch to Bat. O / P when Mains over regulation range | |||||
Over load /short Circuit | Fuse & current linited for both Mains and Battery modes | |||||
Battery | Type | Lead-Acid miantenance-free | ||||
Dc Bus | 12V7.0Ah | 12V9.0Ah | 12V7.0Ah | 12V9.0Ah | ||
Number | 1 PC | 2 PCS | ||||
Recharge time | 8hours≥90% | |||||
Back up time(one PC) | 8-15mins | 10-18mins | 12-20mins | 20-30mins | 25-45mins | |
Physical | Weight (KGs) | 5 | 5.5 | 6 | 10.5 | 11.5 |
Shipping Wt. | 5.6 | 6 | 6.5 | 11 | 12 | |
Product Dimensions (mm) | 335*95*160 | 355*120*195 | ||||
Packing Dimensions (mm) | 375*170*200 | 420*190*250 | ||||
Soft ware | RS232 or USB option Windows & NT | Auto save & shut down | ||||
Function | Cold start | UPS Start The Computer Even there Is no Main Power | ||||
Automatic Charge | Automatic Charge when UPS is off | |||||
Automatic Restart | Automatic Restart if main power coming within one hour | |||||
Voltage display | 220v/230v Optional following the real capacity | |||||
Frequency | 50HZ/60HZ Optioanl following the real | |||||
Beeping | During the battery mode ,the beeping optional | |||||
Efficiency | AC-AC | 1 | ||||
DC-AC | 0.6 | |||||
Acoustic | Noise level | ≤45dB | ||||
Environmental | Temperature | -5-45 DegreeC | ||||
Humidity | 20% to 90% | |||||
Power Outlets | No. and types | 2 SOCKETS | 3 SOCKETS |