Quality trojan 3000 plus UV lamp replacement,long life 13000h with coating,CE RoHS
Electrical Data, with electronic ballast: Anschlussleistung / power input: approx. 300 W Anschlussstrom / mains current: 1.3 A Anschlussspannung / mains voltage *: 230 V Vorschaltger?te Typ / ballast type: EVG 270W, 3.8-4.0A depending on mains voltage conditions of Electronic Ballast * ______________________________________________________________________________ operating conditions: cooling *: enhanced convection operating position: optional Lamp tube temperature (max.): < 150! C, (optimal 100-120!C) * recommended quartz sleeve: 36mm x 1.2-1.5mm ______________________________________________________________________________ Strahlungsphysikalische Daten / radiation data: irradiance at 254 nm: 600uW/cm2 (1m distance) radiation flux at 185 nm *: 0 radiation flux at 254 nm *: 89 W * in air at room temperature Optimal UVC output and lamp efficiency at 100 ¤ 120 deg. C Lamp tube temperature ______________________________________________________________________________ Lebensdauer / lifetime: Abh?ngig von der Betriebsweise / depending on operating conditions expected useful life time: 12000 hours Intensity decrease: 25% at 254 nm after 12000 hours - based on 100 h level These specifications are based on average data and were measured under laboratory conditions.
NNI270/100XL Hanovia amalgam lamp replacement