Welcome to ECBAY
3-channel Ambulatory ECG&BP combiner ,Holter& BP 2 in 1
3-channel Ambulatory ECG&BP combiner ,Holter& BP 2 in 1

1. 3 choices of working modes:ambulatory ECG only, ABPM only or synchronized ambulatory ECG and ABPM. 2.With LCD.

The most desirable, versatile Holter/ABPM device

1. 3 choices of programmable working modes: ambulatory ECG only (3-channel or 12-lead, full-disclosure), ABPM only or synchronized ambulatory ECG and ABPM.

2. Small and smart, the lightweight recorder is very comfortable to wear with little or no need to alter the patient's daily activities.

3. Highly integrated design saves space and improves the performance and reliability, adding to the recorder's durability, impact and shock-resistance.

4. With graphics displayed on LCD, you can view items such as current heart rate, total of beats, ECG of each lead, current or past blood pressure, next BP testing time, battery voltage, the cuff pressure value during inflating and deflating, and the number of beats in the process of BP testing. Visual icons and menu ensure easy access. ECG can be previewed to check electrode and lead connections to ensure high quality signal recognition.

5. Highly anti-jamming electrode connection, to assure universal electrode use while achieving high-quality signals.

6. With special amplifier and A/D convertor circuits, the recorder boasts a high fidelity of signal processing surpassing traditional standards, a 256Hz sampling frequency, a 1/1024 resolution as well as a clear and accurate display of ECG.

7. Reviewable blood pressure recording not only includes tabulated numerical data results, but also provides every artery pulsation waveform for possible review analysis.

8. Innovative intellectualized liquid control system ensures stable pressure and more accurate testing results. Quick inflation and linear deflation are completely imitates the auscultation process of physicians.

9. In the event of ECG abnormalities such as tachycardia, bradycardia and ST changes, the blood pressure testing will be initiated, thus better associating the two with each other. (Needs to be preset)

10. For a patient whose blood pressure jumps suddenly, the cuff will be automatically inflate to the proper pressure.

11. Wide dynamic range automatically adjusts to patients' blood pressures and pulsations.

12. Automatically monitors the battery and automatically stops in the event of a voltage insufficiency.

13. Large memory SD card is adopted to ensure 24-hour recording of comprehensive ECG and ABPM without compression while providing a solid compact size. The recorded data is preserved without damaged in the case of voltage shortage or battery accidentally being removed.

14. Conforms to the international standards with 5 or 7 electrodes for 3-channel, and 10 electrodes for 12-lead.

15. Double MCU, dual sensor, dual valve to ensure that patients will not be subject to excessive pressure or the pressure of a long time. In line with European standards EN 60601-2-30 for safety requirements on blood pressure equipment, it can guarantee security in any single fault condition:

◊ results in a failure of the normal pressure regulating means;

◊ prevents deflation of the cuff within the specified period;

◊ results in a failure of the normal cuff pressurization timing.

16. The wireless infrared interface features real-time monitoring, which not only ensures the proper utilization, but also enables the recorder to be used as a wireless ECG and blood pressure monitoring system.

17. Patient data and account information can be loaded into the recorder in advance to avoid possible mistakes, an appealing feature for multiple recorder facilities.

18. USB 2.0 technology allows quick transfer within seconds, enhancing efficiency.

19. Independent battery voltage recording channel records the 24-hour battery voltage curve that can externally estimate battery capacity and help analyze a possible breakdown.

20. BIOX products have unlimited upgrading potential, thus ensuring future hardware upgrading at minimum costs.

SPECIFICATIONS

           

ECG :

Detecting channel  

3-channel ECG

Independent pacemaker detection

Battery voltage recording channel

Patient Input configuration   

5 or 7 electrodes

Input dynamic range                  

±5 mV ECG, ±300 mV offset voltage

Input impedance

> 10 MΩ

Common mode rejection   

≥75dB

Gain accuracy  

Maximum amplitude error ≤ 10%

Gain stability The change

≤ 3 % over a 24 h period

System noise

< 50 μVp-v

Multi-channel crosstalk  

≤0.2 mVp-v

Frequency response  

  0.05 Hz ~ 40 Hz (±3 dB)

Minimum feature size

50 μVp-v

Timing accuracy  

The overall error during 24 h ≤ 30 s

Sample Rate  

256 Hz/channel

2048 Hz/channel (pacemaker detection)

A/D resolution  

10 bits

Blood pressure:

Method of measurement

Oscillometric method

Indicating range

0 ~ 300 mmHg

Recording range  

Systolic 50 ~ 260 mmHg

Diastolic 30 ~ 180 mmHg

Pressure precision               

≤3 mmHg

All-purpose:

Recording time                

24 hours

Data transfer

Full-disclosure transfer           USB card reader

Pre-set & real-time transfer     Wireless infrared

Storage medium                 

SD card

Memory size                       

256 MB or more

Batteries                                

4 x AA size alkaline batteries

Dimensions                            

124 x 68 x 31(mm3)

Weight                                     

180 g (excluding batteries)

Safety type             

Type B equipment with internal battery continuous operation

PC minimum requirements    

Pentium III 500 MHz or higher 1024 x 768 resolution

System requirements              

Windows 9x/2000/XP/Vista

Standard Configuration: recorder, cuff, SD memory card, lead-wires, pack CD of softeware, infrared adapter,encrypt lock