1. 3 choices of working modes:ambulatory ECG only, ABPM only or synchronized ambulatory ECG and ABPM. 2.With LCD.
The most desirable, versatile Holter/ABPM device
1. 3 choices of programmable working modes: ambulatory ECG only (3-channel or 12-lead, full-disclosure), ABPM only or synchronized ambulatory ECG and ABPM.
2. Small and smart, the lightweight recorder is very comfortable to wear with little or no need to alter the patient's daily activities.
3. Highly integrated design saves space and improves the performance and reliability, adding to the recorder's durability, impact and shock-resistance.
4. With graphics displayed on LCD, you can view items such as current heart rate, total of beats, ECG of each lead, current or past blood pressure, next BP testing time, battery voltage, the cuff pressure value during inflating and deflating, and the number of beats in the process of BP testing. Visual icons and menu ensure easy access. ECG can be previewed to check electrode and lead connections to ensure high quality signal recognition.
5. Highly anti-jamming electrode connection, to assure universal electrode use while achieving high-quality signals.
6. With special amplifier and A/D convertor circuits, the recorder boasts a high fidelity of signal processing surpassing traditional standards, a 256Hz sampling frequency, a 1/1024 resolution as well as a clear and accurate display of ECG.
7. Reviewable blood pressure recording not only includes tabulated numerical data results, but also provides every artery pulsation waveform for possible review analysis.
8. Innovative intellectualized liquid control system ensures stable pressure and more accurate testing results. Quick inflation and linear deflation are completely imitates the auscultation process of physicians.
9. In the event of ECG abnormalities such as tachycardia, bradycardia and ST changes, the blood pressure testing will be initiated, thus better associating the two with each other. (Needs to be preset)
10. For a patient whose blood pressure jumps suddenly, the cuff will be automatically inflate to the proper pressure.
11. Wide dynamic range automatically adjusts to patients' blood pressures and pulsations.
12. Automatically monitors the battery and automatically stops in the event of a voltage insufficiency.
13. Large memory SD card is adopted to ensure 24-hour recording of comprehensive ECG and ABPM without compression while providing a solid compact size. The recorded data is preserved without damaged in the case of voltage shortage or battery accidentally being removed.
14. Conforms to the international standards with 5 or 7 electrodes for 3-channel, and 10 electrodes for 12-lead.
15. Double MCU, dual sensor, dual valve to ensure that patients will not be subject to excessive pressure or the pressure of a long time. In line with European standards EN 60601-2-30 for safety requirements on blood pressure equipment, it can guarantee security in any single fault condition:
◊ results in a failure of the normal pressure regulating means;
◊ prevents deflation of the cuff within the specified period;
◊ results in a failure of the normal cuff pressurization timing.
16. The wireless infrared interface features real-time monitoring, which not only ensures the proper utilization, but also enables the recorder to be used as a wireless ECG and blood pressure monitoring system.
17. Patient data and account information can be loaded into the recorder in advance to avoid possible mistakes, an appealing feature for multiple recorder facilities.
18. USB 2.0 technology allows quick transfer within seconds, enhancing efficiency.
19. Independent battery voltage recording channel records the 24-hour battery voltage curve that can externally estimate battery capacity and help analyze a possible breakdown.
20. BIOX products have unlimited upgrading potential, thus ensuring future hardware upgrading at minimum costs.
SPECIFICATIONS
ECG : | ||
Detecting channel | 3-channel ECG | Independent pacemaker detection |
Battery voltage recording channel | ||
Patient Input configuration | 5 or 7 electrodes | |
Input dynamic range | ±5 mV ECG, ±300 mV offset voltage | |
Input impedance | > 10 MΩ | |
Common mode rejection | ≥75dB | |
Gain accuracy | Maximum amplitude error ≤ 10% | |
Gain stability The change | ≤ 3 % over a 24 h period | |
System noise | < 50 μVp-v | |
Multi-channel crosstalk | ≤0.2 mVp-v | |
Frequency response | 0.05 Hz ~ 40 Hz (±3 dB) | |
Minimum feature size | 50 μVp-v | |
Timing accuracy | The overall error during 24 h ≤ 30 s | |
Sample Rate | 256 Hz/channel | |
2048 Hz/channel (pacemaker detection) | ||
A/D resolution | 10 bits | |
Blood pressure: | ||
Method of measurement | Oscillometric method | |
Indicating range | 0 ~ 300 mmHg | |
Recording range | Systolic 50 ~ 260 mmHg Diastolic 30 ~ 180 mmHg | |
Pressure precision | ≤3 mmHg | |
All-purpose: | ||
Recording time | 24 hours | |
Data transfer | Full-disclosure transfer USB card reader Pre-set & real-time transfer Wireless infrared | |
Storage medium | SD card | |
Memory size | 256 MB or more | |
Batteries | 4 x AA size alkaline batteries | |
Dimensions | 124 x 68 x 31(mm3) | |
Weight | 180 g (excluding batteries) | |
Safety type | Type B equipment with internal battery continuous operation | |
PC minimum requirements | Pentium III 500 MHz or higher 1024 x 768 resolution | |
System requirements | Windows 9x/2000/XP/Vista |
Standard Configuration: recorder, cuff, SD memory card, lead-wires, pack CD of softeware, infrared adapter,encrypt lock
3-channel Ambulatory ECG&BP combiner ,Holter& BP 2 in 1