Welcome to ECBAY
Modern outdoor transfomer substation
Modern outdoor transfomer substation

Rated capacity of Transformer : 80-630kVA LV Rated current :400,630,1250A Rated power frequency withstand voltage:42/48KV

YB1 Modern outdoor Transformer Substations 1.HV Rated voltage:7.2/12KV 2.HV Rated current:630/200A 3.Rated capacity:80-630kVA

YB1 Modern outdoor Transformer Substations

1.HV Rated voltage:7.2/12KV

2.HV Rated current:630/200A

3.Rated capacity:80-630kVA

1.Descriptions and applications:

YB1 series Environment-friendly AC Cubicle type Substation is a compact complete power distribution equipment comprised of the high voltage distribution equipment,transformer,low voltage electric equipment and energy metering device and other distribution facilities which are preassembled in a cubicle.

As a device for accepting and distributing electricity in distribution system,it's used in urban high-rise buildings,urban and rural constructions,residential quarters,small and medium-sized plants,mines,oil fields,temporary construction electricity utilization and other places.

2.Product Model and Implication:

Model     No.: Y  B  1  x - x / x / x - x   x

Explanation No.: 1  2  3   4   5  6    7   8  9

1,2:prefabricated substation;3:design sequence number;4:structural form:M-"B" type configuration,P-"delta"configuration;5:Low rated voltage of transformer kV;6:High rated voltage of transformer V;7:Rated capacity of transformer kVA;8:design scheme of high voltage main circuit;9:design scheme of low voltage main circuit.

Plane layout and overall dimensions:

YB1 series prefabricated substation can be divided into 2 type by arrangement,which are "B" type configuration and "delta" configuration,other type can also be provided according to the demand.

Sketch map of overall appearance:

Type

A

a

B

b

H

The best places of application

3-phase

"B" type configuration

100-630KVA

4140

3750

2590

2290

2320

Mining area,oilfields

800-1250kVA

5184

4880

2500

2290

2626

Construction

"delta" configuration

50-400kVA

2500

2300

2400

2200

2320

Residential communities

Single phase

"B" type configuration

50kVA

2500

2300

1260

1060

2215

Power supply of road lamps

80-100kVA

2500

2300

1840

1640

2215

Note:dimension of diagram are for reference.

3.Main Technical specifications:

Items

unit

numeric

High voltage unit 

(HV)

Rated voltage

kV

7.2,12

Rated frequency

Hz

50

Rated power frequency withstand voltage (1min)

phase-to-ground voltage/phase-voltage

kV

42

Between fracture voltage

kV

48

Rated lightning impulse withstand voltage

phase-to-ground voltage/phase-voltage

kV

75

Between fracture voltage

kV

85

Rated current

Main circuit

A

630

Fuse circuit

A

200

Effective value of rated short-term withstand current (3s)

kA

16,25,25

Rated peak withstand current

kA

40,50,63

Rated breaking current

A

200,630

Low voltage unit 

(LV)

Rated voltage

V

400

Rated current

A

400,630,1250

Effective value of rated short-term withstand current 

kA

30,50

Rated peak withstand current

kA

63,105

Compensation capacity 

kVAr

0-320

Transformer unit (T)

Rated capacity

kVA

80-630

Impedance voltage

%

4;4.5

 

 

 

 

 

 

 

 

Modern outdoor transfomer substation

Related Products
Ads by Google


About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.