Welcome to ECBAY
Multi-parameter Patient Simulator
Multi-parameter Patient Simulator

It is a portable device, which can provide comprehensive physiological waveform to content general test and train requirement.

3.5-inch color TFT touch-screen, 320*240 pixels, friendly operation interface.Display the output waveforms synchronously, which is convenient for user to   compare with the   test equipment.It integrates the functions of SD socket interface, user can output the   custom waveform by this   device.Built-in templates list to provide the waveform that is expressed by each  preset sequence   number,which is convenient for searching.Two operation interfaces:Chinese and English.Operate with keystroke and touch-screen expediently and rapidly.Built-in 3.7V/4000mAh(Rechargeable alkaline battery).Optical external power: AC 220V, 50Hz or AC 120V, 60Hz

ECG/ArrhythmiaECGConventional: All leads have the same voltage with the II-lead as the referenceAmplitude: 0.5,1.0,1.5 and 2.0mVThe accuracy of Amplitude: ±2%ECG Rate:  15,20,25,30,40,60,80,100,120,140,160,180,200,220,240,260,280,300,320,340      and 350 BPMECG artifacts: 50 or 60 Hz, muscle, baseline drift and breathingThe elevation of the ST segment: -0.8 mV to +0.8 mV, the step is 0.1 mVThe default: 80 BPM,1mVArrhythmiaAtrial: Atrial Fib(coarse), Atrial fib(fine), Atrial Flutter, Sinus Arrhythmia,  Missed Beat, Atrial Tachycardia, Nodal Rhythm, Supraventricular TachycardiaVentricular: Vent Fib (coarse), Vent Fib (fine), Premature Ventricular   Contraction (PVC) 6/min,PVCs 12/min, PVCs 24/min, Freqent Multifocal, Bigeminy, Trigeminy, Paired   PVCs, Run 5 PVCs, Run 11 PVCs, Vent Tachycardia, AsystolePremature Beat: Atrial Premature Atrial Contraction (PAC), Nodal PNC, Left  Ventricular Focus PVC1, Early Left Ventricular Focus PVC1, Right Ventricular Focus PVC1, Early   Right Ventricular Focus PVC1, R on T Left Ventricular Focus, R on T Right  Ventricular Focus, Multifocal PVCConduction Defects: First Degree Heart Block, Second Degree Heart Block,   Third Degree Heart   Block, Right Bundle Branch Block, Left Bundle Branch   Block   ECG Performance Testing ECG amplitude:0.5,1.0,1.5 and 2.0mVThe accuracy of Amplitude: ±2%Pulse: 30 and 60 BPM, the width of pulse wave is 60 msSquare: 0.125 and 2.0 HzTriangle: 2.0 and 2.5 HzSine: .0.5, 5, 10, 40, 50, 60 and 100 HzECG Rate:15, 20, 25, 30, 40, 60, 80, 100, 120, 140, 160, 180, 200, 220, 240,  260, 280, 300,   320, 340 and 350 BPMThe accuracy of ECG Rate: ±1%RespirationRespiration Rate: 0 (Apnea), 15, 20, 30, 40, 60, 80, 100, 120 and 150 R/MIINRespiration Impedance: 0.2, 0.5, 1.0 and 3.0 ΩBaseline Impedance:500,1000,1500 and 2000Apnea: 12 s, 22 s, 32 sECG simulator with adjustable heart rate/12-lead output33 kinds of Arrhythmia waveformsPacemaker  Two IBP channelsVariety of respiratory impedance,apnea pauses (0 BrPM) of 12, 22 and 32   seconds.Standard ECG calibrationExport square,triangle and sine with adjustable frequencyIBPThe default: 00/00mmHgDynamic IBPChannel 1: Artery  120/80mmHg               Radial 120/80mmHg               Left Ventricle 120/00mmHg               Right Ventricle 25/00mmHgChannel 2: Artery  120/80mmHg               Radial 120/80mmHg               Left Ventricle 120/00mmHg               Right Atrium 15/10mmHg               Right Ventricle 25/00mmHg               Pulmonary Artery 25/10mmHg               Left Atrium 14/4mmHg

Multi-parameter Patient Simulator

Ads by Google


About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.