Welcome to ECBAY
Strain-controlled Triaxial Apparatus
Strain-controlled Triaxial Apparatus

1. Complies with BS1377, ASTM D2850, D4767 2. Shear speed from 0.00001 to 9.99999 mm/minute

TKA-TTS-6C Strain-controlled Triaxial Testing System                                                                                                             Conforms to BS1377-7, 1377-8, 1924-2, ASTM D2850, D4767, AASHTO T296, T297                                                                                                               The detail info. as follow:

Item

Specifications

Qty

1

TKA cell for 50/ 70/ 100mm diameter samples, which quasistatically controls axial displacement, comprising integral base unit housing axial actuator, control electronics, power supplies to drive same. Maximum cell pressure 2000 kPa. Maximum axial load 10kN. Including top caps and base pedestals for 50/ 70/ 100mm samples plus all tubing and hydraulic connections. Infinitely variable speed from 0.00001 to9.99999mm/min

1

2

TKA load cell (25kN) including load ram, load button and electrical connection for TKA data interface

1

3

TKA load cell (50kN) including load ram, load button and electrical connection for TKA data interface

1

4

TKA pore pressure transducer 2MPa with electric connection for data interface. Accuracy 0.15% of full range output

 

5

De-airing block and valve for pore pressure transducer

1

6

TKA two-channel RS232 Multiplexer (MUX), connects to RS232 port on PC

1

7

1 of TKA 4-channel, 16bit data interface with RS232 interface.

1

8

TKA 2MPa/100cc Advanced digital pressure/volume controller with RS232 port, built in 16 key keypad and liquid crystal display, to give stand-alone or PC control Cell pressure/volume. Automatically protected against pressure and volume over load. Volume accuracy 0.1% of measured value. Pressure accuracy 0.15% of Full Range. Volume change measured and displayed to 1cu.mm (0.001cc). Pressure regulated and displayed to 1 kPa

1

9

TKA 2MPa/100cc Advanced digital pressure/volume controller with RS232 port, built in 16 key keypad and liquid crystal display, to give stand-alone or PC control Back pressure/volume. Automatically protected against pressure and volume over load. Volume accuracy 0.1% of measured value. Pressure accuracy 0.15% of Full Range. Volume change measured and displayed to 1cu.mm (0.001cc). Pressure regulated and displayed to 1 kPa

1

10

Test specimen preparation kits, 38mm/50mm Consisting of 3 part split former, 2 part split mould, suction sleeve stretcher, 20 membranes ,10 porous discs, 2 top discs

1 set

50mm test specimen preparation kit 

1 set

70mm test specimen preparation kit 

1 set

11

Nylon Opaque Tubing.6mm OD.3500kPa.-5merters .The Nylon opaque tubing have an outer diameter of 6.0mm and inner diameter of 4.0mm.This tubing should be able to apply a pressure of 3500kPa

1

Strain-controlled Triaxial Apparatus

Ads by Google


About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.