VC1008 is a low cost, state-of-the-art, maintenance-free infrared carbon dioxide transmitter in the climate zone ......

Applicatoin:

VC1008 is a low cost, state-of-the-art, maintenance-free infrared carbon dioxide transmitter in the climate zone or in the ventilation duct. It can decrease your energy consumption while maintaining a healthier indoor air quality.

Features

Using SenseAir´s patented NDIR technology and offers reliable measurements

two analogue & one relay contact outputs

maintenance-free in normal applications

non-frill design; cost-optimized for connection to DDC/PLC

two different housings

1) IP20 wall mount

2) IP65 duct mount

Specifications 

Operating Temperature Range: 0 - 50°C

Storage Temperature Range: -40 to +70°C

Operating Humidity Range: 0 to 95% RH (non-condensing)

Warm-up Time: ≤1 min. (@ full specs ≤15 minutes)

Sensor Life Expectancy: > 15 years

Maintenance Interval: no maintenance required

Power Input: 24V AC/DC

Power Consumption: <1 W

Sensing method: Gold-plated infrared (NDIR) wave-guide 

technology with Automatic Background Calibration (ABC) and passive gas diffusion

Measurement range: 0-2000 ppm CO2

Repeatability: ± 20 ppm ± 1 % of reading

Accuracy: ± 30 ppm ± 5 % of reading

Drift : <±10 ppm /year

Pressure Dependence: 1.6 % of reading/KPa

Output 1: 0-10 VDC for 0 - 2 000 ppm

Output 2: 4–20mA  for 0 - 2000 ppm

Optional Output 3: N.C. & N.O.: contacts pre-set at 1000ppm

Models:

Model

Specifications

VC1008T

Wall mount CO2 transmitter range

2000ppm

VC1008T-Ks

Duct mount CO2 transmitter range

2000ppm

Option

 

-R

Relay output

Other Ranges

0.6%/2%/4%

Dimension:

Wall mount series (Model: VC1008T)

Dimension: 100 x 80 x 27 mm (L x W x H)

Hole space: 60 mm; According to J-boxes (EU Standard)

Duct mount series (Model: VC1008T-Ks)

Dimension: 142 x 84 x 46 mm (L x W x H)

Probe length: 245 mm (Adjustable)

technology with Automatic Background Calibration (ABC) and passive gas diffusion

Measurement range: 0-2000 ppm CO2

Repeatability: ± 20 ppm ± 1 % of reading

Accuracy: ± 30 ppm ± 5 % of reading

Drift : <±10 ppm /year

Pressure Dependence: 1.6 % of reading/KPa

Output 1: 0-10 VDC for 0 - 2 000 ppm

Output 2: 4–20mA  for 0 - 2000 ppm

Optional Output 3: N.C. & N.O.: contacts pre-set at 1000ppm