Welcome to ECBAY
ADFC12AD Dissolution System of Sampling and Collection
ADFC12AD Dissolution System of Sampling and Collection

Consists of RC12A Dissolution Tester, RZQ 12D Sampling and Collection System. Once 12 cups of dissolution test can be executed.

ADFC12AD Dissolution System of Sampling and Collection

ADFC12AD Dissolution system of sampling and collection is consists of RC12A Dissolution Tester, RZQ-12D Sampling and Collection System. Once 12 cups of dissolution test can be executed. Automatically and accurately complete dissolution and sampling process.

Features1. Dissolution Tester provided with 12 vessels and 12 shafts. 2. Automatically positioning shafts with vessels in coaxiality, easy to handle and use.3. Dissolution Tester head lift electronically.4. Separate design for sampling system and collection system.5. Sampling and Collection System adopt precise glass injector as sampling drive.6. Using 12 channels of valve with high precision and high chemical stability.7. Anti-absorption of polytetrafluoroethylene tubing with high chemical stability.8. Adopting filter?Infiltration technology before the experiment to reduce absorption.9. The cross-contamination is avoided because of adopting circulation technique of return liquid to before sampling and pipe emptying technology after sampling.10. It has equal liquid supplement function.11. With 12 channels separate piping systems12. Sampling with two-stage filtration, using10 μm diameter of cylindrical filter head in the initial filtering, not filter or 0.8 μm / 0.45 μm/ 0. 2μm aperture of φ25 mm injection type filter can be chosen according to actual needs in the second filtering.13. Testtube rack of 16 lines, for up to 96 test tubes.14. Sealed silicon rubber cap for test tube to avoid sample evaporation and contamination.15. Big screen LCD display, easy operation.16. Clean solution is replaceable during tubing clean.17. Power-on password, Easy to manage instrument.18. Dissolution sample collection system consistent with domestic and international pharmacopoeia of drug dissolution and sampling requirements.

Specification1. Rotating speed: 25-250 rpm.±4%2. Temperature control: 5°C(room temperature) to 45°C.±0.3°C 3. Number of sampling channels: 124. Max. sampling times: 85. Max. sampling interval: 99 hours 59 minutes6. Min. sampling interval: 1 minute for the first one; 4 to 6 minutes for others (according to sampling volume and solution supplement )7. Continuous operating duration: 99 hours 59 minutes x 88. Sampling filtration time: ≤ 30 seconds9. Sampling volume (or amount of adding volume): 1 ml to 10 ml10. Sampling accuracy: ± 2% When sampling volume is 5ml, each channel average11. Filtering aperture: 10μm polyethylene filter at first filtering        Φ25mm injection cellulose filter at second filtering         Diameter up to 0.22μm12. Sampling point position: midpoint between top of basket or paddle and liquid surface 10mm distance from inner wall of the vessel13 Reserved communication Interface ,you can communicate with the PC through cable or LAN

ADFC12AD Dissolution System of Sampling and Collection

Ads by Google


About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.