Welcome to ECBAY
Digital PID Temperature Controller
Digital PID Temperature Controller

temperature controller 1.display precision prior to 0.2FS 2.input signal:All signal 3.Power: AC85-242V

  PID Temperature Controller

  PID Temperature Controller adopts modular structure,further improve overall performanceThe meter is operated with 4-keys,dual row 4-LED display for displaying the measurement value and set value or measurement value and output value, with manual /automatic switch and setting itself functionwith characteristic of small volumelow power consumptionconvenient operationsteady and reliable of runningThey are now widely used for the automatic control system over the area of machinery, chemical, ceramics, light industry, metallurgy, petrifaction, heat treatment industry.

Technical standard :

1.display precision prior to 0.2FS 2.input signal:All signal 3.Power: AC85-242V

1. Input and rangeone meter can be compatible

 

    (1)  Thermocouple: K (-50~1300oC), S (-50~+1700oC), T (-200~+350oC), E (0~800oC), J ( 0~1000oC), B (0~1800oC), N (0~1300oC), WRe (0~2300oC)

 

    (2)  Thermal resistance: CU50 (-50~150oC)  PT100 (-20~600oC)

 

    (3)  Linearity voltage05V15V01V0100mV020mV

 

    (4)  Linearity currentwith diffluent resistance010mA020mA420mA

 

    (5)  Linearity input: -1999~+9999 (user freely setting)

 

2. Precision

 

    (1) Input by thermal resistance , linearity voltage and linearity current 0.5F.S±1

 

    (2) Thermocouple input adopt copper resistance or freezing compensate cold end 0.5 F.S±1

 

    (3) Although the meter can measure B, S, WRE during the temperature 0~600oC,its measurement  could not reach 0.5 class

 

    (4) differentiate rate1, 0.1

 

3. Response time: ≤0.5s (filter parameter sets 0)

 

4. Adjusting mode

 

  (1) ON/OFF control methodReturn difference can be adjusted

 

  (2) Common PID controlwith the parameter of self-setting function

 

  (3) Intelligence adjustment(including vague PID adjustment and advanced control algorithm with the parameter of self-setting function)

 

5. Output specificationit make out directly output parameter modularity or without modularity

 

    (1) The switch of relay contact point outputopen+ closed250VAC/7A or 30VDC/10A

 

    (2) SSR voltage:12VDC/30mA(apply for driving SSR relay)

 

    (3) Contact point output with controllable silicon: can contact 5~500A two directions controllable silicon;2 separate directions controllable silicon opposite direction parallel. 

 

    (4) Liner electric current output initial current and terminal current value can be defined when the output is 0~24mAvoltage range 11~23VDC

 

6. Communication

 

   Support RS485communication mode,adopt AIBUS communication agreement,and baud rate support the below selection 1200bps4800bps7200bps9600bps

 

7. Alarm:

 

Support two passive contact output,relay contact 250VAC/7AIt has four methods including upper limit, lower limit, positive deviation ,negative deviation .It can output 2 ways at most

 

8. Tolerance for pressure when it is segregatedBetween electric power ,relays contact and signals end ,do 2000V pressure tolerance test 1s,there is  no abnormal phenomenon;

 

9. Movement with hand: Automatic /Manual

 

10. Power supply:

 

  (1) 85V-242VAC,50-60HZpower consumption ≤4W

 

  (2) 24VDC/AC power consumption≤4W

 

  (3) 220VAC±10% 50HZpower consumption≤4W               

 

11. working circumstance

 

Environment temperature:0~50,humidity ≤85,no corrode and strong electromagnetism disturb

 

12. Product authentication

 

XMT*-808 series temperature meter acquire CE authentication and ROHS Environmental Protection authentication.

 

 

 

 

 

 

 

 

 

 