Vice-gun probe
Main characteristics and applicability
The sublance probe is one kind has the composite function measurement probe is rapid, accurate, direct measurement, appropriate control etc.
Second-ranking model and function
Generation yards
Said Ming
specifications
KZ
KeHai longhua automation
The length
2000
mm
function
TSO
With steel temperature measurement, oxygen content and sampling three functions.
TSC
With measuring molten steel temperature and carbon content and sampling three functions.
TO
With steel temperature measurement, oxygen content two functions.
TS
Has the molten steel temperature measurement, sampling two functions.
T
With steel temperature measurement function.
thermocouple
Indexing number
(S)
Platinum rhodium 10 - platinum
(R)
Platinum rhodium 13 - platinum
(B)
Platinum rhodium 30 - platinum rhodium. 6
Ex. : has the molten steel temperature measurement, oxygen content and acquisition steel sample three functions, match S indexing thermocouple type expressed as: KZ - TSO (S).
Machine parts
Accessories name
specifications
explain
Gun head
KZ - QT - X
The specifications for the X said indexing date;
Provide S and B, R three indexing number
Spiral wire
KZ - DX - X
The holding device
KZ - BC
Second-ranking technical indexes
Type,
Steel sample size
Measured quantity van circumference
Measuring precision
Response time
Have effect rate
KZ - TSO
Flat oval
Double thickness steel sample
Φ 38 x 6.45
Oxygen concentration: 100 ~ 1300ppm
Temperature degrees: °C 1760 600 ~
Temperature measurement: + 5 °C
Measuring oxygen: + 2mV
Measuring oxygen acuities 8s
Temperature measurement acuities 5s
Measuring oxygen p 90%
Temperature measurement p 95%
Sampling p 95%
KZ - TSC
Set carbon: 0. 20% below
Temperature measurement: + 5 °C
Set carbon: acuities 0.02%
Temperature measurement acuities 5s
Set carbon acuities 15s
Measuring temperature > 95%
Set carbon reached more than 90%
Sampling greater than 95%
Second-ranking product "purchase schemes
1 protection caps, Temperature measurement components; 2. The oxygen components; 3. Sampling components; 4. Incoming sample components; 5. 6. Sampling injector, Set carbon components; 7. 8. Set carbon injector, 9. Connectors, Protecting tube 10.
Second-ranking use method
1. Will probe into probe bins.
2. Will probe onto the sublance, in conduction favorable conditions measurements.
3. When measuring the required control to probe in the molten steel the settling time, generally not greater than 8s.
4 the test is finished after the sublance return to timely will probe from the sublance discharged, lest because probe protection tube combustion and damage the sublance connectors.
Vice-gun probe