Welcome to ECBAY
Platinum rhodium 30/6 wire
Platinum rhodium 30/6 wire

Platinum rhodium30/6wire 1.Model:S, R, B TYPE; 2.Min.diameter:0.1mm; 3.Class:I level 4.Using temperature range:0-1600 degree

Platinum rhodium 30/6 wire(B-TYPE thermocouple wire)

The MIN. diameter is 0.1mm.

Platinum and rhodium wire - wire galvanic technical parameters

Thermocouple No. species and sub-degree

Use temperature range C

Variety

No. graduated

Platinum-Rhodium 10 - Platinum

S

0~1600

Platinum-Rhodium 13 - Platinum

R

0~1600

Platinum-Rhodium 30 - Platinum6

B

600~1700

When a reference client for the 0 C, the thermocouple and the Tolerance level to allow deviations

Thermocouple

Grade

Use temperature rangeC

Allowable deviation

B

II

600~1700

±0.25%t

III

600~800

±4 C

800~1700

±0.5%t

R

I

0~1100

±1C

1100~1600

±(1+(t-1100)×0.003) C

II

0~600

±1.5 C

600~1600

±0.25%t

S

I

0~1100

±1°C

1100~1600

±(1+(t-1100)×0.003)C

II

0~600

±1.5 C

600~1600

±0.25%t

Platinum rhodium 30/6 wire