Welcome to ECBAY
500W switching 12v 40a power supply UL approved
500W switching 12v 40a power supply UL approved

1.Input:110V/220V or 100-240 VAC 2.Frequency:50-60Hz 3.Output: 12V 4.Approvals:CE,UL 5.100% full load burn-in test

model/specificationSP-500-12SP-500-13.5SP-500-15SP-500-24SP-500W-27SP-500-48
DC output voltage(V)1213.515242748

Output voltage error

±1% ±1% ±1% ±1% ±1% ±1%
Rated output current(A)403632201810
Output current range(A)0-400-360-320-200-180-10
Wave & Noise240mVp-p 240mVp-p 240mVp-p 240mVp-p 200mVp-p 300mVp-p
Inlet stability±0.5%±0.5%±0.5%±0.5%  ±0.5%  ±0.5%  
Load stability(Note5)±1%  ±0.5%±0.5%  ±0.5%  ±0.5%  ±0.5%  
DC output power(W)480 486 480 480 486 480 
Efficiency 84% 84 %83%85.5% 86.5% 87% 

Adjustable range for DC

voltage(V)

10-13.2 12-15 13.5-1820-26.4 24-30 41-56 

AC input voltage range

88-132VAC/176-264VAC, BY SWITCH, 47-63Hz,124-370VDC

AC input current(A) 

7A/115V, 3.5A/230V

Power factor

0.95/100 ,240VAC

AC impulse current

18A/115V, 36A/230V

Leakage current 

<3.5mA/240VAC

Overload protection

105%~135% TypePULSING HICCUP SHUTDOWN Reset: auto recovery

Over-voltage protection

 

Fan control,O.T.P

temp.coefficient 

RTH1 OR RTH2>=50 FAN ON,<=45 FAN OFF,>=70 Cut off output ±0.03%(050)

Setup,rise,hold up time

1.5s,50ms,20ms

Vibration

10500Hz,2G 10min./1cycle,Period for 60min,EACH AXES

Withstand voltage

Input and output interval3KVAC,Input and enclosure1.5KVAC Output and enclosure0.5KVAC

Isolation resistance

Input and output interval,Input and enclosure,Output and enclosure500VDC/100M Ohms

Working temp. & humidity

-10+50,20%90%RH

Store temp.& humidity 

-20+85,10%95%%RH

Overall dimension

180*120*95mm

Weight 

1.8Kgs

Safety standard 

UL1950,TUV EN60950

EMS standard

IEC1000-42,3,4,5,6,8,11 IEC100-3-2

Note:

1.The testing condition for the parameter above is:230VAC input,  rated load,25 70%Rh,Humidity2.Error,include the setting error, line stability and load stability.(Note:5)3.Wave test:adoptingA12double wire for 20MHz,and 0.1uF&uF capacitor short-circuit for interrupting4.Inlet voltage stability test: when is over load, the lowest voltage of inlet is representative to the highest voltage.5.Load stability test: The load is from 0% to 100%,others 60%.6.C2311must be knocked down.

500W switching 12v 40a power supply UL approved

Ads by Google


About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.