Welcome to ECBAY
Neutral grounding resistor(NGR),China
Neutral grounding resistor(NGR),China

THT-ZT resistor inserted between neutral and ground of a transformer serves to limit fault current to a safe predetermined level

1. About us:

Baoding TIanwei Hengtong Electric company is a domestic professional manufacture of power system neutral earthing equipments and complete implements ISO9001 quality management system. We have a excellent sales performance all over the world and have been exported to more than 40 countries.

 

2. Principles:

THT-ZT Neutral Grounding Resistors are designed to provide added safety to industrial distribution systems by limiting ground fault current to reasonable levels. In a typical solidly grounded three phase system, the neutral is tied directly to earth ground. This can cause high ground fault current (typically 10,000 to 20,000 amps) and excessive damage to transformers, generators, motors, wiring, and associated equipment. Inserting an THT-ZT Neutral Grounding Resistor between neutral and ground limits fault current to a safe level (typically 25 to 400 amps) while still allowing sufficient current flow to operate fault clearing relays.

3. Service conditions:

3.1 Ambient temperature: -40°C~60°C

3.2 Altitude: less than 4000m

3.3 Relative humidity: less than 95% (25°C)

3.4 Rated frequency: 50/60HZ

3.5 Location: outdoor/indoor

 

 

4. Characteristics:

 

4.1Designed in strict accordance with IEEE Standard 32

 

4.2High efficiency of electric conductivity and high-temperature endurance nichrome resistor

 

4.3Corrosion resistant aluminized zinc steel,stainless steel,cold-roll steel enclosures.

 

4.4Corrosion resistant stainless steel A2-70 screws

 

4.4 LZZBJ9 resin casting insulation enhanced type current transformer

4.5 Hidden binding structure Air-cooling system

 

4.6 Sealed cubicle with highest protection level of IP55.

 

4.7 Intellect controlled unit realize the unattended operation  

 

4.8 Fully factory assembled - no field assembly required

4.9 A zigzag connecting grounding transformer is needed when the transformer windings adopt delta connection. 

 

5. Regular Technical Particulars for reference

 Type

Rated Voltage(KV)

Short Time Current(A)

Flow Time (S)

Resistance Value(Ω)

Outer Dimensions(mm)

THT-ZT-6/34.64

6

100

10

34.64

1200x1200x1870

THT-ZT-6/17.32

6

200

10

17.32

1200x1200x1870

THT-ZT-6/8.66

6

400

10

8.66

1200x1200x1870

THT-ZT-6/5.77

6

600

10

5.77

1200x1200x1870

THT-ZT-10/14.43

10

400

10

14.43

1200x1200x1870

THT-ZT-10/9.62

10

600

10

9.62

1200x1200x1870

THT-ZT-10/7.22

10

800

10

7.22

1200x1200x1870

THT-ZT-10/5.77

10

1000

10

5.77

1200x1200x1870

THT-ZT-35/20.21

35

1000

10

20.21

2760x2600x2000

THT-ZT-35/10.10

35

2000

10

10.10

2760x2600x2000

Notes: manufactures various resistors according to the customer’s requirement, the design inaccuracy is ±3%, the flow time is various from 10s, 15s,30s, 60s,2h.

6. Information needed to quote: 

6.1 System Voltage

6.2 Line-to-Neutral Voltage

6.3 Current Rating

6.4 Maximum Time On

6.5 Current Transformer Ratio, capacity (if applicable)

6.6 Grounding Transformer KVA Rating, connection symbol and the transformation ratio (if applicable)

6.7 Material of the enclosure:aluminized zinc steel,stainless steel or cold-roll steel

6.8 IP protectional grade

6.9 Color

6.10 Installing place

6.11 Line mode.

Neutral grounding resistor(NGR),China

Ads by Google


About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.