1.has different attachment 2.temperature compensating function 3.has kinds of species
CLRD THERMAL RELAY
APPLICATION
This series of thermal relay can be used in the circuit of 50Hz or 60Hz,rated insulation voltage 660V,rated current 0.1-96A for protecting the phase break when the electric motor is overload.The relay has different mechanism and temperature compensation & can be plugged in CLRD series AC contactor.It is the most advanced thermal relay in the nineties in the world.
Different thermal overload relays for using with fuse | ||||||
Compensated relays with manual or automatic reset,with relay trip indicator,for AC or DC . | ||||||
Relay setting range | For using with | Reference | Weight | |||
aM | gG | BS88 | contactor LC2- | |||
A | A | A | A |
Class 10A(1)with connection by screw clamp teminals
0.10...0.16 | 0.25 | 2 | - | D09...D38 | CLRD-01 | 0.124 |
0.16...0.25 | 0.5 | 2 | - | D09...D38 | CLRD-02 | 0.124 |
0.25...0.40 | 1 | 2 | - | D09...D38 | CLRD-03 | 0.124 |
0.40...0.63 | 1 | 2 | - | D09...D38 | CLRD-04 | 0.124 |
0.63...1 | 2 | 4 | - | D09...D38 | CLRD-05 | 0.124 |
1...1.7 | 2 | 4 | 6 | D09...D38 | CLRD-06 | 0.124 |
1.6...2.5 | 4 | 6 | 10 | D09...D38 | CLRD-07 | 0.124 |
2.5...4 | 6 | 10 | 16 | D09...D38 | CLRD-08 | 0.124 |
4...6 | 8 | 16 | 16 | D09...D38 | CLRD-10 | 0.124 |
5.5...8 | 12 | 20 | 20 | D09...D38 | CLRD-12 | 0.124 |
7...10 | 12 | 20 | 20 | D09...D38 | CLRD-14 | 0.124 |
9...13 | 16 | 25 | 25 | D12...D38 | CLRD-16 | 0.124 |
12...18 | 20 | 235 | 32 | D18...D38 | CLRD-21 | 0.124 |
16...24 | 25 | 50 | 50 | D25...D38 | CLRD-22 | 0.124 |
23...32 | 40 | 63 | 63 | D25...D38 | CLRD-32 | 0.124 |
30...38 | 50 | 80 | 80 | D32 and D38 | CLRD-35 | 0.124 |
17...25 | 25 | 50 | 50 | D40...D90 | CLRD-322 | 0.510 |
23...32 | 40 | 63 | 63 | D40...D90 | CLRD-3353 | 0.510 |
30...40 | 40 | 100 | 080 | D40...D90 | CLRD-3355 | 0.510 |
37...50 | 63 | 100 | 100 | D40...D90 | CLRD-3357 | 0.510 |
48...65 | 80 | 100 | 100 | D50...D90 | CLRD-3359 | 0.510 |
55...70 | 80 | 125 | 125 | D50...D90 | CLRD-3362 | 0.510 |
63...80 | 100 | 125 | 15 | D65 and D96 | CLRD-3363 | 0.510 |
80...104 | 125 | 160 | 160 | D80 and D96 | CLRD-3365 | 0.510 |
80...104 | 125 | 200 | 160 | D115 and D150 | CLRD-4365 | 0.900 |
95...120 | 160 | 200 | 200 | D115 and D150 | CLRD-4367 | 0.900 |
110...140 | 100 | 250 | 200 | D150 | CLRD-4369 | 0.900 |
80...104 | 125 | 160 | 160 | (2) | CLRD-33656 | 1.000 |
95...120 | 160 | 200 | 200 | (2) | CLRD-33676 | 1.000 |
110...140 | 250 | 200 | (2) | CLRD-33696 | 1.000 |
Class 10A(1)with spring terminal connections(for direct mounting on the contactor only)
0.10...0.16 | 0.25 | 2 | - | D09...D38 | CLRD-013 | 0.140 |
0.16...0.25 | 0.5 | 2 | - | D09...D38 | CLRD-023 | 0.140 |
0.25...0.40 | 1 | 2 | - | D09...D38 | CLRD-033 | 0.140 |
0.40...0.63 | 1 | 2 | - | D09...D38 | CLRD-043 | 0.140 |
0.63...1 | 2 | 4 | - | D09...D38 | CLRD-053 | 0.140 |
1...1.7 | 2 | 4 | 6 | D09...D38 | CLRD-063 | 0.140 |
1.6...2.5 | 4 | 6 | 10 | D09...D38 | CLRD-073 | 0.140 |
2.5...4 | 6 | 10 | 16 | D09...D38 | CLRD-083 | 0.140 |
4...6 | 8 | 16 | 16 | D09...D38 | CLRD-103 | 0.140 |
5.5...8 | 12 | 20 | 20 | D09...D38 | CLRD-123 | 0.140 |
7...10 | 12 | 20 | 20 | D09...D38 | CLRD-143 | 0.140 |
9...13 | 16 | 25 | 25 | D12...D38 | CLRD-163 | 0.140 |
12...18 | 20 | 32 | 32 | D18...D38 | CLRD-213 | 0.140 |
16...24 | 25 | 50 | 50 | D25...D38 | CLRD-223 | 0.140 |
Thermal overload relays for using with unbalanced loads |
Class 10A(1) with connection by screw clamp terminals |
Change the prefix in the reference above from LRD(except LRD-4...)to LRD-D |
Example:LRD-01 becomes LR3-D01. |
Thermal overload relays for using on 1000V supplies |
Class 10A(1) with connection by screw clamp terminals |
(1)Standard IEC947-1specifies a tripping time for 7.2 times the setting current IR:class 10A:between 2 and 10 seconds. (2)Independent mounting. |