Welcome to ECBAY
Cat. 4 Relay SR4P2A1Y
Cat. 4 Relay SR4P2A1Y

Manual and automatic resent Redundant circuit Short circuit self-test Plug-in terminal

1.Basic introduction 

SR series safety relays is a new type of safety relays,beautiful appearance,structure compact,and reach to the best safety by the smallest cost.SR series safety relays is a kind of products designed according to the European design standards,certified by European safety standard CE and has achieved national CCC safety certification,correspond to 2006/42/EC,2004/108/EC,EN ISO 13849-1,EN 60947-4-1,EN 60947-5-1 and so on standards. Safety relays are widely used in safety light curtain,safety door,a sudden stop switch and so on safety and sudden loop, can set double channel operation to make sure security, to prevent accident and stop.

 2.Technology specification

Supply voltage

85-264V AC/DC

Power consumption

3 W

Frequency range

50-60 HZ

Switched capacity(EN60947-5-1)

AC-15,5A/250V

DC-13,6A/24V

Output contact

2N/O,1N/O(t)

Contact fuse protection

4A T/6A F

Max overall cable resistance input circuit

DC 100ohm

Dual-channel with detection of shorts across contacts

AC 100ohm

Switch-on delay(automatic reset)

35ms

Switch-on delay(manual reset)

30ms

Delay-on

10ms

Max supply interruption before power failure

1s

Shake suitability

EN60068-2-6

Frequency

10-55Hz

Amplitude

0.33mm

Protection housing

IP50

Max cable cross section

0.2-2.5mm2

Dimention

96x22.5x116

Weight

340g

Mounting

35mm DIN rail

3. Detail introduction

SR series safety relay controls one set light curtain, is mounted inside the electrical cabinet.

SR series safety relay is directly inserted into 35mm rails of the inside electrical cabinet of press or equipment.

If periphery has strong electromagnetism noise source(for example transducer,high frequency machine and so on),the controller should be far away from them to avoid the interference.

(1)Output various form,widely  application.

(2)The input contacts's short citcuit fault can be detected,safety performance is good.

(3)You can choose manual reset or automatic reset,operation convenience.

(4)It has self monitoring redundancy circuit ,safety performance is good.

(5)It has status indicators,facilitate fault ispection.

(6)It has removable terminals,facilitate installation and connection.