Welcome to ECBAY
Thermal overload protection relay LR2-F53 JR28-F53
Thermal overload protection relay LR2-F53 JR28-F53

1.Used with CJX2-F(LC1-F) contactor 2.Rated voltage up to 690V 3.Rated current up to 150A 4.Telemecanique (Shineider) standa

1.Specification

LR2(JR28,VR28) series thermal overload relay are suitable for overload and phase-failure protection of ACmotors with frequency of 50/60Hz, voltage up to 690V, current up to 0.1-150A under 8-hours duty or uninterrupted duty.Functions provided by these relays, are phase-failure protection, ON/OFF indication,temperaturecompensation, and manual/automatic reset.Applicable Standards: National Standard: GB 14048. International Standard: IEC 60947-4-1The relays can be mounted onto contactors or installed as single units.2.Operation condition

(1)The altitude couldn t exceed 2000m.(2)Ambient temperature: -5 ~+55 and the average temperature no more than +35 in 24hours.(3)Atmosphere: Comparative humidity no more than 50% at max +40 , and it may be higher at a lower temperature. The lowest average temperature no more than +20 in the wettest month.The maximum average comparative humidity of this month couldn t exceed 90%, The change of temperature leading to dew on the product must be considered.(4)Class of pollution: Class 3.(5)The slope between installation surface and vertical surface couldn t exceed 5o.(6)Keeping away from explosive, corrosive and electric atomy.(7)Keeping dry.(8)The product should be used and installed at certain place without any shock, vibration etc.

3. Main Technical

 

TypeNumberSetting range (A)For contactor
JR28-2513010.1~0.16CJX2-09~32
13020.16~0.25CJX2-09~32
13030.25~0.4CJX2-09~32
13040.4~0.63CJX2-09~32
13050.63~1CJX2-09~32
13061~1.6CJX2-09~32
13071.6~2.5CJX2-09~32
13082.5~4CJX2-09~32
13104~6CJX2-09~32
13125.5~8CJX2-09~32
13147~10CJX2-09~32
13169~13CJX2-09~32
132112~18CJX2-09~32
132217~25CJX2-32
JR28-36235323~32CJX2-09~32
235530~40CJX2-09~32
JR28-93332217~25CJX2-09~32
335323~32CJX2-09~32
335530~40CJX2-09~32
335737~50CJX2-09~32
335948~65CJX2-09~32
336155~70CJX2-09~32
336363~80CJX2-09~32
336580~93CJX2-95
JR28-150436580~104CJX2-95
436795~120CJX2-95~115
4369110~140CJX2-115
TypeNumberSetting range (A)For contactor
JR28-150536990~150CJX2-150
JR28-200F535730~50CJX2-F115~F185
F536348~80CJX2-F115~F185
F536760~100CJX2-F115~F185
F536990~150CJX2-F115~F185
JR28-630F5371132~220CJX2-F225~F265
F7375200~330CJX2-F225~F500
F7379300~500CJX2-F225~F500
F7381380~630CJX2-F400~F630

Motion Characteristic: Three-phase Balance Motion Time

NoTimes of the setting currentMotion timeStart conditionAmbient temperature
11.05>2hCold state20±5oC
21.2<2hHeat state(Following the No.1 test)
31.5<4min
47.210A2s< Tp≤10s≤63ACold state
104s< Tp≤10s>63A

Phase-losing Motion Characteristic

NoTimes of the setting currentMotion timeStart conditionAmbienttemperature
Any two phasesAnother phase
11.00.9>2hCold state20±5oC
21.150<2hHeat state(Following the No.1 test)

4.Packing detail

ModelCarton size(CM)CTNWEIGHT
PCS(kg)
JR28-2551.5*25.5*30.510017
(LR2-D13)
JR28-3644*39.7*24.37520
(LR2-D23)
JR28-9344*39.7*24.35023
(LR2-D33)
JR28-15044*39.7*24.35023
(LR2-D43)
JR28N-2546.5*27.5*33.510015
(LRD-13)
JR28N-3644*39.7*24.37520
(LRD-23)
JR28N-9344*39.7*24.35023
(LRD-33)
JR28-20047*29*40.53024
(LR9-F53)
JR28-63047*29*40.51827
(LR9-F73)

5.Overall and Mounting Dimmensions

6.The time-current curves characteristic

7.Accessory

8.Product photo 

 

Thermal overload protection relay LR2-F53 JR28-F53

Ads by Google


About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.