4078 replace G5V 2 PCB micro relay
1. 4078 replace G5V 2 PCB micro relay 2. 2A switching capacity 3. High sensitivity: 150 mW
Contact Data
Contact Form | 2C | ||||||
Contact Material | Au + Ag | ||||||
Contact Ratings | 1A: 120VAC; 2A/24VDC | ||||||
Max.Switching Voltage | 240VAC/60VDC | ||||||
Max.Switching Current | 2A | ||||||
Max.Switching Power | 120VA/30W | ||||||
Initial Contact Resistance | 50mΩ Max.at 6VDC 1A | ||||||
Life Expectancy Electrical | 100,000 Operations (rated load) | ||||||
Life Expectancy Mechanical | 100,000,000 Operations (no load) |
General Data
Insulation Resistance | 100M Ω Min at 500VDC | ||||||
Dielectric Strength Between Open Contacts | 500VDC 50-60HZ(1 minute) | ||||||
Dielectric Strength Between Contacts And Coil | 1000VDC 50-60HZ(1 minute) | ||||||
Operate Time | 6ms max | ||||||
Release Time | 4ms max | ||||||
Ambient Temperature | -30°C to +70°C | ||||||
Shock Resistance | Malfunction | 10G | |||||
Destruction | 15G | ||||||
Vibration Resistance | 10-55Hz,1.5mm double amplitude | ||||||
Ambient humidity | 40-85% RH | ||||||
Weight | Approx.5g | ||||||
Safety Standard | UL CE CQC |
Coil Data (@20°C)
Rated Voltage (VDC) | Coil Resistance Ω (±10%) | Max Operate Voltage (VDC) | Min Release voltage (VDC) | Max Applied Voltage (VDC) | |||
0.15W | 0.2W | 0.36W | 0.45W | ||||
3 | 60 | 45 | 25 | 20 | 2.25 | 0.15 | 3.9 |
5 | 167 | 125 | 70 | 50 | 3.75 | 0.25 | 6.5 |
6 | 240 | 180 | 100 | 80 | 4.5 | 0.3 | 7.8 |
9 | 540 | 405 | 225 | 180 | 6.75 | 0.45 | 11.7 |
12 | 960 | 720 | 400 | 320 | 9 | 0.6 | 15.6 |
24 | 38400 | 2880 | 1600 | 1280 | 18 | 1.2 | 31.2 |
48 | - | 11520 | 6400 | 5100 | 36 | 2.4 | 62.4 |
Outline Dimension
PC Board Layout & Wiring Diagram (Bottom View)
4078 replace G5V 2 PCB micro relay