Portable wireless digital dental X-ray machine
Portable wireless digital dental X-ray machine

Portable X-ray machine

Features:

1.Power: 24V 8000MA Charger: 220V/110V, 50Hz 2. Tube current: 8mA 3. Frequency: 30 KHz 4. Exposure time: 1-9 seconds optional 5. Leak radiation: < 20gy/h 6. Rating: 60W 7. Focus Skin Distance: >20cm 8. Tube voltage: 70kVp 9. Relative humidity (RH): <80% 10. Storage conditions: 5-40 degrees Celsius, relative Humidity 11. Net weight: 2.5 kg

Include:

1 X Main Unit

1 x Dental Film Position Indicator

1 x Charger

5 x Dental Films for Commissioning

1 x Packing Instruction

1 x Warranty Card

1 x Large Packing Box

Non-film inspection and storage can be realized when corresponding to a sensor.

Packing List:  

1.    Ball Head 

2.    Other accessories for test. (Kodak Films,etc.)

The Composition and Use of the Equipment

The machine is mainly used in dental clinics,to check out before treatment,and to be used for comparison and confirmation during and after treatment. It is an indispensable piece of equipment for daily work within a clinic. Some examples of its use include checking tissue structure,the depth of the root,the degree of inflammation,and for the inner inspection of broken teeth.

While using a small amount of radiation there is no need for protection. Hospitals have purchased this machine to take films of fingers and toes by the side of a patient's bed.

Operation of the Main Unit

1.    Upon receiving,open the box and check the product for possible damage during shipping.

2.    Make sure the fittings on the encasement list are packaged within the box.                          

3.    Install the blue ray tube to the foreside of the ball head,then tighten it.

4.    Turn on the Power;the pilot lamp will be light up.During this time,the digital tube  will show the fore setting time. Now the equipment is in standby mode.

5.    Setting the time (Skip to next step if unneeded) Use the "SET", buttons to reset the time as follows: press SET,the pilot lamp above is illuminated, the machine is now in the time setting mode then press  and to set the time needed (time range is 1-9seconds); press set again when the time is adjusted the light lamp is off. The equipment is now in standby mode.

6.       Put the Tooth film plumb behind the tooth which is going to be taken picture, and be as close as possible (the smooth side stick to the tooth)

7.    Keep the ball head plumb to the tooth projection position; Have the ball head,tooth, and tooth film steadily mutually plumb.

8.    After positioning,use the ON/OFF on the main Unit, to take pictures. (Notice: gently press 0.5 sec to turn it on)

9.    After exposure to the tube,press the start button again  in case of an emergency to stop shooting and return to standby status. (At this point there was no output ray,so the dental films can be used again).

10.  Repeat step 6 to reset the picturing time.To repeat the picturing process,please repeat steps 7 to 9.

11.  Turn the power  off when the work is finished,press POWER, making sure the pilot lamp is off.Don't keep the machine long in standby mode.

Developina the Dental film

1.    Picture the tooth following the right operating procedure of the X-ray Unit,then take the film out from the mouth.

2.    Use a syringe to extract 4-5 mi of imaging liquid.

3.    Transfuse the liquid into the bag,nip both the ends and the sides of the bag with thumbs and first fingers(knead the film).

4.    Open the end of the bag about ten minutes after transfusing the liquid into the bag.

5.    Take the film out,put it into clear water,and rinse it. Don't wipe the surface of the film with the surface to prevent damage to the image.

6.    Observe and diagnose after the film becomes dry.

Warranty

We offer a 1 year warranty as follows.

(Note: When warranty expires,we charge for the replacement and repairs of the machine and components.)

The following cases are not within the scope of this warranty:

l  Intentional damages to the machine which cannot be repaired.

l  Opening the machine for purposes of reverse engineering for means of imitation.

l  Getting burned using the wrong power supply.

l  Modifications to the machine,such as the addition of extra components to the machine resulting in damage that prevents the normal use

  

Portable wireless digital dental X-ray machine