Welcome to ECBAY
4-20mA Diaphragm Sealed Flange Remote Differential Pressure Transmitter
4-20mA Diaphragm Sealed Flange Remote Differential Pressure Transmitter

1.high quality competitive price 2.stable,Anti-Vibration,shock resistance 3.reversed polarity,OVP 4.2.5~100kPa

Functional Instruction

Sealed diaphragms are used for prevention of medium in the pipelines directly entering pressure

sensors assembly in the differential pressure transmitters, which are connected with transmitters

with the help of capillary tubes filling fluid inside.

   

HHGP/DP Smart diaphragm sealed differential pressure transmitters are used for measuring flow rate, density 

and pressure of gas, liquid and steam , and then outputs  4~20mA DC power signal corresponding 

to measured differential pressure. They can communicate with Hart system, remote set and monitor can be set.

Standard Technical Specification

• Measurement Scope

Capsule

   Range

       Scope 

M

2.5~100kPa

(250~10000mm H2O)

-100~100kPa

(-10000~10000mmH2O)

H

25~500kPa

(0.25~5kgf/cm²)

-500~500kPa

(-5~5kgf/cm²)

• Output signal:4~20mA DC with 2 wire system of digital communication

• Ambient Temperature:

   -40~85°C(-40~185oF)(general model)

   -30~80°C(-22~176oF)(with LCD gauge head)

• Fluid Touching temperature: referring to sheet 1

• Ambient Humidity: 5~100%RH@(when 40°C)

• Working pressure: 2.7kPa abs(20mmHg abs)

                  ~rated working pressure of flange

• Static pressure influence: referring to Sheet 2-1, 2-2 and 2-3

• Power Voltage Variation Influence:

       ±0.005%/V(21.6-32)V DC, 350Ω

• Erection: Transmitter: 2-inch pipeline erection

          Diaphragm Sealed Parts: flange erection

• Diaphragm Sealed Part Material:

     Diaphragm and other fluid touching parts: referring to "model and specification code list"

• Capillary Tube: JIS SUS 316

• Protection Tube: JIS BUS 304

• PVC Shied(PVC maximum usage temperature: 100°C)(212o F  )

• Filling Liquid: silicone oil or inert liquid

• External Zero Adjustment: it can be adjusted continuously

• Resolution: 0.01% of range

• Zero Adjustment: whatever negative migration value and positive migration value, it can be set

 within the measured range of kinds of capsules within upper and lower limit of the measurement 

scope.

PLS CONTACT US FOR MORE INFORMATIONS ! we will reply asap. 