Welcome to ECBAY
Neutral Grounding Resistor
Neutral Grounding Resistor

Neutral Grounding Resistor Ambient Temperature: -40 - 40celsius Max Elevation: 3000m Max Humdity:95% Current:1-2000A

 Neutral Grounding Resistor

Professional6-20kv Indoor Neutral Grounding Resistor (NGT) Power Distribution Equipment 

FUNCTION

Neutral Grounding Resistors are used to protect power transformers, 

power generators and other associated equipment in your power systems 

against 50/60 Hz faults (short circuit) and transient phenomena (lightning).

SPECIFICATIONS

There are six parameters needed to specify the neutral grounding resistor.1. Rated voltage line to neutral or system voltage.

2. Rated fault current.

3. Rated “duration time” of the line to neutral voltage not exceeding the allowable

 temperature rise.

4. Rated Resistance.

5. Application environment, indoor or outdoor.

6. Enclosure material, ss plate or normal cold rolled sheet.

RANGE

• Rated current: from 1 amp to 2000 A

• Rated voltage: from 0.4 to 35kV

• Rated Resistance: from 1 ohm to 2000 ohm

• Rated time: 1 sec to continuous time rating

TESTING AND QUALITY

All Mingrui Neutral Grounding Resistors are designed, rated, manufactured and

tested in strict compliance with IEEE-32. Routine tests performed on each Neutral

Grounding Resistor are measurement of resistance, high voltage power frequency, 

insulation measurement, aspect verification, dimensional control. Mingrui’s internal 

quality system has been developed and certified under ISO 9001 quality system

CONSTRUCTION

Standard unit includes the stainless steel resistor assembly plus all the required

 insulators, internal connections and hardware installed in a standard safety 

enclosure. Neutral Grounding Resistor units are completely assembled, prewired, and 

tested at our facility. For shipping all units are crated for added protection and ease of handling.

ENCLOSURE FEATURES

• Forged eyebolts in all four corners for easy hoisting.• Removable front and rear louvered covers for easy access for connection and inspection.

• Corrosion resistant nameplate provides complete ratings and manufacturers information.

•Heavy gauged enclosure polyester powder coated finish provides maximum protection.

ENCLOSURE OPTIONS

•Stainless steel, cold rolled plate construction. Custom paint finish is available.• Top or side mounted entrance bushing(s).• Screened covers for indoor applications.• Support stands for elevating the enclosure above ground.

OPTIONS

• Current or groundingl transformers mounted and prewired at our facility• ON or OFF Load disconnecting switches

Operating Environment

    1.Indoor application

     2.Environment temperature between -40°C and +40°C

     3. Altitude does not excess 3000m

     4. Rlative humidity is not more than 95% (25°C)

     5.Power grid frequency: 58~62Hz(60Hz system),48~52Hz(50Hz system)

     6.No corrosive gas or stem and no explosive dust on installation site.

To serve you better, please kindly offer following information when ordering

6.1 generator rated voltage, transformation ratio of grounding transformer, resistance value;

6.2 insulation form of grounding transformer;

6.3 transformation ratio of current transformer ;

6.4 color of cabinet, wiring from the top or bottom;

6.5 time of current flowing-through

6.6 material and color of box, IP protective grade, colour and installation location.

     

( function(){ var aBigImageSrc = [ 'http://i00.i.aliimg.com/photo/v19/409231184_1/Neutral_Grounding_Resistor.jpg' , 'http://i00.i.aliimg.com/photo/v19/409231184_2/Neutral_Grounding_Resistor.jpg' , 'http://i00.i.aliimg.com/photo/v19/409231184_3/Neutral_Grounding_Resistor.jpg' , 'http://i00.i.aliimg.com/photo/v19/409231184_4/Neutral_Grounding_Resistor.jpg' , 'http://i00.i.aliimg.com/photo/v19/409231184_5/Neutral_Grounding_Resistor.jpg' ]; var oProductShow = new AE.run.minisite.productShow(); oProductShow.init( { 'aImgSrc': aBigImageSrc } ); } )(); Neutral Grounding Resistor

Ads by Google


About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.