10KV Zno surge arrester for distribution 1.Model:YHW 2.System Nominal Voltage:3~6KV 3.GB 11032-2000 JB/T8952-2005.

  10KV Zno surge arrester for distribution 

 

Zincoxide (ZnO) surge arrester is one of the important apparatus for GIS in the power system and its normal running has significant influence on the performance and reliability of GIS.

 

The Metal ZnO Arresters (MOA) are important over-voltage protection device. They are widely used in electric power system due to their excellent nonlinear and high surge absorbing capability. And it is one of the most important equipments in electric power system. Whether its running status is good or not directly affects other equipments in sub stations.

 

Using the ZnO surge arrester to prevent the shunt capacitor from overvoltage is one of the most efficient and reliable measures, and in many cased it is a necessity.

 

Metal Oxide Surge Arrester (MOA) is one of the most important equipments in electric power system. Whether its running status is good or not directly affects other equipments in sub stations.

 

Using the ZnO surge arrester to prevent the shunt capacitor from overvoltage is one of the most efficient and reliable measures, and in many cased it is a necessity.

Application of  zno surge arrester   :

 

Zinc Oxide Arrester will protect the power equipment in power system from damage of atmospheric overvoltage and switching overvoltage.

 

Working condition:

 

1. Environment temperature: -40--+40 degree

2. sea level elevation:<1000m

3. 48HZ<supply frequency<62HZ

4. Power frequency voltage should not be more than continuous running voltage

5. Max wind speed should be less than 35m/s

6. Earthquake intensity should be less than 7 degree

7. If used in contamination area, should be noted in advance.

 

Manufacturing standard:

Chinese National Standard

Accord with Chinese national technical requirements GB 11032-2000 JB/T8952-2005, JB/T 10497-2005, DL/T815-2002

 

Parameters of zno surge arrester:

 

Usage

Model

Rated  Voltage

System Nominal Voltage

Continuous working voltage

DC reference voltage

Not less than

Max residual voltage

Steep Wave Impule

KV)

Lightning Impule

(KV)

Distribution

YH5WS-12.7/50L

12.7KV

10KV

6.6KV

25KV

57.5

50

YH5WS-16.5/50L

16.5KV

10KV

12.7KV

25KV

57.5

50

YH5WS-17/50L

17KV

10KV

13.6KV

25KV

57.5

50

YH5WS-17.5/50L

17.5KV

10KV

13.6KV

25KV

57.5

50