Welcome to ECBAY
high voltage three phase oil filled power transformer
high voltage three phase oil filled power transformer

1.oil filled power transformer 2. ISO 3.Low noise&environmental protection 4.Low no-load loss Distribution Transformer

 

10kv oil filled  power transformerNormal Operation Conditions

 

1.Installation site: outdoors or indoors

2.Altitude: less than 1000M

3.Ambient temperature: -25oC~+40oC

4.Maximum relative humidity: 95%(25oC)

5.Earthquake-resistant capability: the horizontal acceleration of ground surface is 0.3g, and the vertical acceleration of ground surface is 0.15g

concurrently acting continuous three sine waves, safety factor ≥1.67

6.All-weather working capability in outdoor environment

7.The equipment has certain capability in dustproof, antifouling, waterproof, earthquake resistance and shock resistance

Note: Transformers operating in special environment are available upon the demand of customers.

 

Standard of Products

GB1094.1-1996, GB1094.2-1996, GB1094.3-2003, GB1094.5-2008, GB1094.7-2008, GB/T6451-2008, etc

 

Performance Parameter List

Rated

capacity

(kVA)

Voltage combination and tap range

Connection

Group

No-load

loss

(W)

75oC load loss

 

(W)

No-load

current

(%)

Impedance

voltage

(%)

High

voltage

(kV)

Tap

(%)

Low

voltage

(kV)

10

6

6.3

6.6

10

10.5

11

±5

±2×2.5

0.4

0.69

Yyn0

Dyn11

Yzn11

55

310/325

2.80

4.0

20

70

480/500

2.50

30

100

600/630

2.30

50

130

870/910

2.00

63

150

1040/1090

1.90

80

180

1250/1310

1.90

100

200

1500/1580

1.80

125

240

1800/1890

1.70

160

280

2200/2310

1.60

200

340

2600/2730

1.50

250

400

3050/3200

1.40

315

480

3650/3830

1.40

400

570

4300/4520

1.30

500

680

5150/5410

1.20

630

810

6200

1.10

4.5

800

980

7500

1.00

1000

1150

10300

1.00

1250

1360

12000

0.90

1600

1640

14500

0.80

2000

2000

17400

0.70

5.0

2500

2400

20200

0.60

   3150

2800

24000

0.50

Note: 1. Load loss values above the oblique line in the table are applicable to the Yyn0 connection group, and the values below the oblique line are applicable to the Dyn11 or Yzn11 connection group. 

  

2. The list shows main performance parameters of a three-phase duplex winding off-circuit-tap-changing distribution transformer. Customized transformers of different specification are available upon the demand of users.

    

high voltage three phase oil filled power transformer

Ads by Google


About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.