Welcome to ECBAY
overhead lines
overhead lines

Detailed Product Description


Aerial Bundle Cable (ABC cable), 0.6/1KV, XLPE insulation, Aluminum Conductor

Product Description

1. Application of Service Drop Cable:
Service Drop Cable(ABC CABLE) are mainly used for electric power tranmission, rebuiding of urban and forest regions. They can improves safety and reliance of electrified wire netting.

2. Type of Service Drop Cable:
Service Drop Cable(ABC CABLE) covers mainly three types:
Duplex Service Drop
Triplex Service Drop
Quadruplex Service Drop

The cable can be produced whose construction is phase conductor with neutral bare conductor or phase conductor with insulated neutral conductor, etc. And we can still produce the cables according to the request of customers.

3. Detaild Introduction of Service Drop Cable
3.1 Duplex Service Drop

Applications
To supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volts or lower at a conductor temperature of 75 maximum.

Construction
Concentic strand or cmpressed 1350-H19 conductor, polyethylene or cross linked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy nertral messenger.

3.2 Triplex Service Drop
Applications
To supply power from the ulility`s lines to the consumer`s weatherhead. For service at 600 volts or less(phase to phase ) at a conductor temperature of 75 maximum for PE insulation or 90 maximum for XLPE insulation.

Construction
Concentic strand or cmpressed 1350-H19 conductor, polyethylene or cross linked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy nertral messenger.

3.3 Quadruplex Service Drop
Applications
Used to supply 3 phase power, usually from a pole-mounted transformer to the use`s servic head where connection to the service entance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperature not to exceed 75 for PE insulated conductors or 90 for XLPE insulated conductors.

Construction
Conductors are concentrically standed, compressed 1350-H19 aluminium. Insulated with either polyethylene or XLPE. Neutral messengers aer concentrically stranded 6210 AAAC, AAC or ACSR.

 

Standards:
1. B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
2. B-231 Aluminum Conductors, Concentric-Lay-Stranded.
3. B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
4. B-399 Concentric-Lay_Stranded 6201-T81 Aluminum Alloy Conductors.
5. B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
6. Duplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474


Item#
 


Phase Conductor

 Size AWG
 


Phase

Conductor

Stranding
 


Phase Conductor

Insulation Thickness
 


Bare Neutral

Messenger

Size AWG
 


Bare

Neutral Strand
 


Bare Neutral messenger Breaking Strength
 


Weight Per 1000ft - XLP
 


Weight Per 1000ft - Poly
 


Rating - XLP
 


Rating-Poly
 


Pekingese
 


6
 


Solid
 


45 mls
 


6
 


7/w
 


563 Lbs
 


63.5 Lbs
 


61.7 Lbs
 


70 Amps
 


70 Amps
 


Collie
 


6
 


7/w
 


45 mls
 


6
 


7/w
 


563 Lbs
 


66.8 Lbs
 


63.1 Lbs
 


70 Amps
 


70 Amps
 


Dachshund
 


4
 


Solid
 


45 mls
 


4
 


7/w
 


881 Lbs
 


95.5 Lbs
 


93.4 Lbs
 


90 Amps
 


90 Amps
 


Spaniel
 


4
 


7/w
 


45 mls
 


4
 


7/w
 


881 Lbs
 


100.5 Lbs
 


95.4 Lbs
 


90 Amps
 


90 Amps
 


Doberman
 


2
 


7/w
 


45 mls
 


2
 


7/w
 


1350 Lbs
 


152.7 Lbs
 


145.7 Lbs
 


120 Amps
 


120 Amps
 


Malemute
 


1/0
 


19/w
 


60 mls
 


1/0
 


7/w
 


1990 Lbs
 


242.6 Lbs
 


234.2 Lbs
 


160 Amps
 


160 Amps
 

Ads by Google


About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.