1.DC 3V,5V,6V,12V,24V,AC 100V,200V,110V,220V 2.air fluid 3.pressure range: 0-0.7Mpa 4.temperature:-10-50 (No freezing)
Solenoid Specifications
Series | V114/V124 | V114A/V124A | |
Electrical entry | Grommet (G)/(H), L plug connector (L) M plug connector (M) | ||
Coil rated voltage (V) | DC | 24,12,6,5,3 | |
AC |
| 100,110,200,220 | |
Poer consumption | ±10%
| ||
Apparent power | DC | With power saving circuit: 0.1W Standard with indicator light only: 0.4W | With indicator light only: 1.1W |
AC |
| With indicator light only 110V: 1.7VA 220V: 2.6VA | |
Surge voltage suppressor | √ | ||
Indicator light | LED |
Fluid | Air |
Pressure range of use | 0-0.7Mpa |
Port size | M5×8 |
Ambient and fluid temperature °C | -10-50°C (No freezing) |
Response time | ON: ≤5ms OFF: ≤4ms |
Max. operating frequency | 20Hz |
Manual override | Non-locking push type, push-turn locking slotted type |
Lubricantion | Not required |
Mounting orientation | Unrestricted |
Impact/Vibration resistance | 150/30m/s² |
Enclosure | Dustproof |
Valve Model | Type of actuation | Model | 1→2 | 2→3 | Weight(g) with sub-plate | |||||
C[dm³/(s.bar)] | b | Cv | C[dm³/(s.bar)] | b | Cv | Grommet | L,M plug connector | |||
V114 | N.C. | Standard | 0.037 | 0.11 | 0.018 | 0.018 | 0.35 | 0.015 | V1-4:27 V1-4A:30 | V1-4:26 V1-4A:29 |
V114A | N.C. | Large flow capacity | 0.076 | 0.07 | 0.016 | 0.099 | 0.23 | 0.024 | ||
V124 | N.O. | Standard | 0.054 | 0.35 | 0.015 | 0.037 | 0.11 | 0.007 | ||
V124A | N.O. | Large flow capacity | 0.099 | 0.23 | 0.024 | 0.076 | 0.07 | 0.016 |