Welcome to ECBAY
Mobile Laser Therapy Unit <GOOD Performance>
Mobile Laser Therapy Unit <GOOD Performance>

Laser Therapy Unit 1.Glow voltage of laser tube>28kv 3.Power output of laser tube40w 4.Over current protective device

Mobile Laser Therapy Unit <GOOD Performance>

Purpose

It is mainly used in cutting, evaporation, scorching, coagulation, and raying of human body to achieve

 medical purpose.

For a long time, Carbon Dioxide Laser Medical Instrument has found wide application and effectiveness

 in treatment has been acknowledged publically.

Summary

CO2 laser therapy equipment is a mobile laser medical equipment designed for medical treatments of 

commonsurgery, skin, etc. in various hospitals and clinic.

The instrument is in good laser pattern, laser is transmitted by light conduction system with small facular 

point, high concentration of power, wavelength of biological effect, less damage to organization outside 

focus. 

In medical operation, special aiming indicator is used to indicate medical point with precise location.

Powerful output of laser enables temperature of organization focused to rise up to 200°C which results in rapid evaporation of water inside cell and denaturalization, coagulation and death,

 carbonization of protein organs and vaporization of solution intra cells. Therefore, it is characterized by 

short time of operation, less wound and good effect,.

Unique advantages

1. Standing structure, easiness and convenience in operation, comparatively large area of operation.

2. Joint arm equipped for laser transmission is rotatable without limit, location of height can be balanced.

3. Power of output laser is of high steadiness and even in any position.

4. Power of laser can be preset freely and preset output power and working current can be displayed.

5. Touch film switch is used for easy regulation and control as well as beautiful and elegant appearance.

6. Indicating light for aiming is distinct with correct calibration and good overlapping performance with

 medical laser.

7. Various safety functions are available and efficient. Light and easy to be moved. With self-diagnosis indication of state.

Technical specifications

Power Supply of User's Grid

1. Power supply  Mono-phase DC220V±22V, 50Hz±1Hz, 10A

2. Mono-phase 3-polarity socket should be used with correct grounding wire and grounding resistance below 4Ω

Capacity of Medical Instrument

1. Power of complete instrument: 800w or below,  Current of power supply: below 6A

2. Fuse of power supply: 5*20mm 6A, 2pieces

3. HV fuse: diamater 5*20mm 5A, 1piece

4. Pump fuse:diameter 5*20mm   2A, 1piece

Carbon Dioxide Laser (for treatment)

1. Wavelength of laser: 10.60um

2. Terminal output of laser power: Max is not below 22.4W, non-step preset continuously.

3. Unsteadiness of terminal output laser power is superior to ±15%

4. Repetition of terminal output laser power is superior to ±10%

5. Facular diameter of laser: 0.5mm or below

6. Film pattern of laser: Multiple film

7. Rated working voltage: DC220V (adjustable scope :100V~250V)

8. Voltage of carbon dioxide laser: DC15kv

  

Technical parameters:

Room temperature

5° to 40°

Relative humidity

<80%

Power supply

AC220V±10%50Hz

Power capacity

<1000VA

External dimension

1500×540×580

Weight of the unit

103kg

Work conditions:

Wavalength of laser output

10.6

Mode of laser output

low valence

Power output of laser tube

≥35w continuously adjustable

Glow voltage of laser tube

≥28kv

Rated working current

≤20mA

Parts pictures:

As professional factory in China, we have confidence that we could help you out for

 your future business and we both can get profit. ^_^

Mobile Laser Therapy Unit <GOOD Performance>

Ads by Google


About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.