M6200 JUPITER THERMOPLASTIC HALF-MASK EN 105006
M6200 JUPITER THERMOPLASTIC HALF-MASK EN 105006

1)TPE half-mask fitted with elasticated straps 2)EN 105006 3)with EN140:1998 standard.

 Name:M6200 JUPITER THERMOPLASTIC HALF-MASK

Size:SingleColour:Blue0082

Description :Thermo-plastic elastomer half mask (TPE). Elastic straps. Intended for 2 filtering cartridges of M6000 serie, sold separately.

Materials:Half-mask : TPE.Elasticated straps

Instructions for use:This respiratory half-mask is designed to protect against dust, vapours and gases.It is adviced to keep the respiratoryprotection on when leaving the contaminated working area and until there are no more contaminated particles on the clothes.

Limits to use:Do not use this equipment out of its usage specifications defined in the instructions above. Do not use the mask in anoxygen-deficient atmosphere (< to 19% of air volume) or in an atmosphere too rich in oxygen (> to 25% of air volume). Do notuse the mask to fight fire, to sandblast or to protect yourself against contaminants excluded or non-covered by the warningsmentioned on filters. This mask protects neither the eyes nor the skin against vapours or gases which may burn or irritate the skin, in case of absorption or penetration. Users with side-pieced spectacles, beards and other face pilosity must expect thata tight fit to the face will not be possible.

Instructions for storage:The mask should be stored in a clean room away from heat and sunlight. The filters should be stored at a temperaturebetween -5°C and +35°C with maximum relative humidity of 75 %. If the filters are not stored in their original packaging or inthe recommended storage conditions, the expiry date indicated on the filter may no longer be valid.Instructions for cleaning / maintenance:Clean all the components with soapy water and disinfect the inside of the mask with an antiseptic solution. Do not use petrol,chlorine or organic based solvents. Rinse with clean water. Shake to eliminate surplus water. Check the valves for damage. Ifthey are damaged, the mask should be replaced. Test for tightness. Do not clean the cartridges.

Performances :This equipment complies with the European directive 89/686, notably regarding ergonomics, innocuousness and comfort, andwith EN140:1998 standard.