Benchtop Automatic Calorimeter
Benchtop Automatic Calorimeter

Benchtop Style! Quick Analysis! True Isoperibol!

Features of 5E-C5500 Automatic Calorimeter

Multi-StandardsProviding analysis under ISO, ASTM, GB/T standard for different requirement. 

New Quick MethodThe analysis time of Quick Method: 10~11 minutes.This method has good resistance of ambient temperature fluctuation 

New Classical MethodThis method has good resistance of ambient temperature fluctuation.

Feasible PlacementThis Calorimeter consists of Controlling unit and Temperature Controlling unit.User shall place these two unit on the bench, or separately place the Temperature Controlling unit below the bench.

Stable Water QuantityThe reliable quantitative measuring cup ensures the long term stability of water quantity.

Simplified Water WayThe Calorimeter adopts 3 pumps and 3 valves.Comparing with traditional water way, this new water way is more simplified and reliable, as well as convenient maintenance.

Constant Water TemperatureA controller of cool water will display the reservoir temperature in real time and adjust the temperature.

Filtering of WaterAddling a filter in the bucket, which prevents the impurities (such as Ignition wire) in bucket from damaging the pump and valve of water way.

Observable Liquid LevelConvenient observation adopted to control the water filling speed, and timely fill water after long-term analysis.

Locked Bucket LidThe bucket lid is locked that ensures the safety and reliability of analysis, additionally, the upper cover of bucket will not be affected by external air flow.

Multi-analysis ModeThis Calorimeter has two analysis modes: Normal Method and Quick Method.

Bomb IdentificationThe system shall identify two different bombs:User can conduct analysis by these two bombs alternatively to use Calorimeter effectively.

Stable Internal EnvironmentUser shall fill water through bucket lid, the large volume of jacket and no water in the bucket drain pipe ensures that the surrounding area of bucket is stable.

Unique Analysis ProcedureJudging the temperature difference between bucket and jacket before igniting, washing the bucket and bomb after analysis:Providing a stable environment before analysis, and removing heat residual after analysis.The residual heat can be eliminated after analysis, not affecting the next analysis.