Welcome to ECBAY
Quick BOD B-1 Tester
Quick BOD B-1 Tester

1) BOD Tester 2) Measurement method:Biosensor 3) Measurement range:0-20 mg/l (base Measurement range) 4) Electrode Monitors

Advanced technology Principle

An oxygen electrode monitors the change in respiratory action caused by the consuming of organic matter by bacteria. The bacteria (trichosporon cutaneum) are incorporated into the oxygen electrode. When a solution containing organic matter is fed to the microbe electrode sensor, the microbes ingest the organic matter, increasing respiratory action and in turn the consumption of oxygen. The amount of oxygen passing through the microbe membrane decreases resulting in a change in the current, which is output by the dissolved oxygen electrode. This change corresponds to the concentration of organic matter.

 

The Quick BOD  B-I takes significant steps to do away with the weaknesses of biosensor BOD measuring apparatus entailed by trouble and time required to replace and load microbe membrane and,with an exchangeable electrode unit that makes it easy to use right away,provides improved operability and maintainability standard and buffer bacteriostatic solutions and antibacterial  tubing allow stable measurements over the long term. The dedicated shipping and recovery box for Used and replacement electrode units may be reused any number of times and the exclusion of apparatus environmentally friendly and easy to use .

  

Specifications

Model

Quick BOD B-1

Measurement method

Biosensor (JIS K3602)

Measurable

Liquid samples containing soluble organic matter such as drainage and river water

Measurement range

0-20 mg/l (base Measurement range)

Variable with pump rpm and sample

Contact time

Measurement time

60 min/specimen assuming calibration for each specimen)

Calibration

Single-point calibration with glucose glutamic solution

Readout

LCD, 20 characters x 2 lines

Precision up to 0.1 mg/L

Reproducibility

Full-scale within ±5%

Output

Recorder output  (0-5 V analog output)

Hot output (0-5 V analog output)

Printer output (Printy3 serial thermal printer)

Temperature controller

Adjustable within 35±0.2

Rated power source

AC 100V±10V,50/60HZ,3A max

Dimensions

370(w)×350 (d) ×300 (h)mm

Weight

14kg

Ambient temperature

5-40

Ambient humidity

90% RH max (Without condensation)

Peripherals

Standard solution, buffer solution, antibacterial tubing set, printer

Features #1 Operability and Maintainability

    Exchangeable microbe electrode units make operation smoother and less time-consuming than loading and replacing conventional membranes.

    Once mounted, electrode units may be used immediately.

    Electrode units may be used for one month continuously or for three months intermittently with standard samples. (Electrode units should be stored in refrigerators when not taking measurements.)

    Front panel allows simple, pushbutton operation.

    Compact size, taking up little space.

    Ease of replacement by installing electrode units or tubing into the opened door in the front panel.

    Anti-reflux valves and antibacterial tubing reduce the frequency of maintenance.

Features #2 Stability

    Bacteriostatic is mixed into standard and buffer solutions, so measurements are stable over the long term.

    Measurements in regions of low concentration are especially stable.

    High correlation with officially certified methods.

Features #3 Applicability

    Changing pump rpm or sample contact time allows measurements in regions of high concentration.

    The optional microbe fixation kit enables the use of other microbes and, therefore ,a variety of water samples.

Features #4 Environmental Friendliness

    Making no use of dangerous reagents and emitting no harmful effluents, the Quick BODB-I is environmentally friendly.

     Used electrode units are recovered with a dedicated shipping and recovery box, and replacement electrode units are shipped with the same dedicated box.

Principle of Microbe Electrode Measuring Method

Apparatus for the estimation of biochemical oxygen demand (BOD) with microbial sensor JIS K 3602-1990 (established Sept.1, 1990) Although the BOD (JIS K 3602) microbe electrode method and BOD5 (JIS K 102) 5-day method are different, the expected BOD5 value can be approximated from the BOD value. This enables water quality to be monitored over a short period of time in order to permit any necessary measures to be enacted as separate standard.

Application areas

Determination applies to surface water and domestic sewage, industrial effluents in the BOD.