Welcome to ECBAY
types of lighting arrester
types of lighting arrester

1 Metal Oxide varistor 2 Polymer housing 3 with mounting bracket 4 with disconnector 5 ISO certificate

 NO.1 Brief Introduction:

 

Lightning arrester (surge arrester) housed in porcelian and polymer housings, is developed to protect switchgear, overhead lines, transformers, and other equipment against atmospheric or a system-immanent over-voltage.

In medium-voltage distribution systems the arresters are widely spread over the whole network as they are normally directly arranged either, for instance, at the pole-mounted transformers, or at the cable terminations.

 NO.2 Construction:

 

Certain designs of the polymer housed arresters were in fact impossible to construct until the gapless metal-oxide technique was introduced. As a major progress, metal oxide arresters could be built with only one single effective active element, namely the column of the metal oxide resistors. High demands are, however, made on these metal oxide resistors, as they combine all the functions, which previously had been shared among the different components of the gapped arrester. In this way they have to be ageing resistant while being subjected to constantly applied operating voltage. They must be able to absorb the energy injected during a discharge, and they should subsequently limit the follow current (leakage current) to value small enough for thermally stable operation.

The metal oxide resistor column, together with the accompanying supporting construction comprises the active part of the arrester. The column consists of individual metal oxide resistors stacked on top of each other. The metal oxide resistors are almost always produced in a cylindrical form. Their diameter decisively determines the energy absorption and the current carrying capability. It is within a range of about 30mm when used for distribution systems and up to 100mm or more for high and extra-high voltage systems and special applications, for which high energy absorption capabilities are required.

NO.3 Characteristics:

Non-tracking and low erosion rates in polluted an non-polluted environments, long term weather ability,resistance to thermal ageing,UV resistance,chemical resistance.Tough, tear and impact resistance.

NO.4 Technical Parameters:

 

ModelArrester Rated VoltageMCOV1/10μs Steep Current Impulse8/20μs Lightning Current Impulse30/60μs Switching Current Impulse2ms Rectangular Current Impulse4/10μs High Current Impulse
kV(r.m.s) <kV AkA
HY10W-332.5510.388.1250100
HY10W-665.120.51615.5250100
HY10W-997.65312522250100
HY10W-10108.4332724250100
HY10W-11119.436.43027.5250100
HY10W-121210.238.53329250100
HY10W-151512.746.54135250100
HY10W-181815.3564942.5250100
HY10W-21211765.55749.5250100
HY10W-242419.5756556250100
HY10W-272722847463.5250100
HY10W-303024.4938272250100
HY10W-333327.51019079250100

 

 

NO. 5 More Photos & Drawing:

  

  

P.S.:

Safety and reliability are vital in high-voltage products and Wenzhou Mingneng Electric Co., Ltd is committed to pioneering improvements in performance for our customers at all levels. Our development teams work to generate a superior range of high performance products. All products developed using our extensive service experience and within the constraints of international standards including IEC and many national standards.

If you are interested in any item of our products, please don't hesitate to inquire us.

types of lighting arrester

Ads by Google


About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.