Welcome to ECBAY
PI7800 SERIES AC drives
PI7800 SERIES AC drives

PI7800 SERIES AC drives(0.2-220KW) ) Novel structure design Complete upgrade of the software Optimized production techniqu

Applicationsmechanics, electronics, metallurgy, mining, petrochemical, transportation, building materials, municipal, metal processing, textile, printing and dyeing, paper making, Injection machine, central air conditioning, numerical control machine tool, air-compressor, fan and pump, blower, air conditioner for large buildings; wastewater treatment system; water supply system for large buildings; public water supply system and other industries and fields.

Brief IntroductionNew PI7800 Family inverter supplies the more comprehensive motor control solution to you. It employs the advanced technology of PWM control and vector control, high performance power module and DSP control. It is with internal current loop to realize high precision of close loop control and reach the stability and precision of current and frequency. Completely new manufacture technique and test equipment ensures the better stability and reliability of the product. Characteristic Novel structure design; Complete upgrade of the software; Optimized production technique; Mature test equipment.Standard Specification:

itemsspecifications
powerVoltage and frequencySingle-phase 200~240V,50/60Hz    Three-phase 200~240V,50/60Hz Three-phase 380~415V,50/60Hz    Three-phase 440~460V,50/60Hz Three-phase 575V,50/60Hz        Three-phase 660V,50/60Hz Three-phase 1140V,50/60H
Allowable Fluctuation rangevoltage: ±15%   frequency: ±5%
controlControl systemhigh performance vector control inverter based on DSP
Output frequencyG/F/Z/S/T/M:0.00~800.0Hz,the maximum frequency range is 10.00~800.0Hz H:0.00~2000.0Hz,the maximum frequency range is 10.00~2000.0Hz.
control methodV/F control, V/F+ PG control, vector + PG control
waveform produce methodsasynchronous space vector PWM, step less and subsection synchronous space vector PWM,2 phase optimized vector PWM
Auto torque boost functionRealize low frequency (1Hz) and large output torque control under the v/f control mode.
Accelerate /decelerate controlAcceleration/Deceleration S curve subsection set mode. The maximum running time is 26 hours.
Program running control7 step speed program running, the maximum running time is 88 hours.
frequency setting accuracyDigital references:0.01Hz(300 Hz and below),0.1 Hz(above 300 Hz) Analog references:0.05Hz/60Hz
frequency accuracySpeed control tolerance 0.01%(25°C±10°C)
V/F curve modeLinear,square,8 V/F curve set by user
Over load capabilityG/S:150% for one minute, 200% for 0.1 second F:120% for one minute, 150% for 0.1 second Z/M/T:180% for one minute, 250% for 0.1 second H:250% for one minute, 300% for 0.1 second
slip compensation0~10% automatic slip compensation
runningInput  signalrunning methodKeypad/Terminal/Communication mode
frequency settingThere are 11 frequency setting modes, including DC 0~10V, DC 0~20mA, DC 4~20mA, potentiometer on the keyboard.
start signalforward, reverse
Multi-segment speedcan set 7 steps speed at most(using multi-function or program running)
Multi-segment accelerationAt most 8 steps acceleration can be set (using multi function terminals or program running.)
instant stopInterrupt controller's output.
traverse runningProgram control running
jogrunning in low speed
fault resetWhen the protection function is affective, system can reset fault state automatically.
PID feedback signalDC 0~10V, DC 1~5V, DC 0~20mA, DC 4~20mA
runningOutput signalrunning statemotor state display, stop, accelerate/decelerate, seven-speed, program running state
fault outputrelay fault output: AC 250V 5A, DC 30V 5A
analog output2 analog output, 8 signals could be selected: frequency, current, voltage, temperature, etc, the output signal range is 0~10V/0~20Ma.
output signal6 output signals, each one with 32 signals for option.
running functionLimit frequency, skip frequency, torque difference compensate, reverse protection, automatic adjustment, PID control
DC brakeOn base of non-OC, internal PID can regulate braking current to ensure enough braking torque.
Protection functioninverter protectionOver voltage, under voltage, over current, over load, overheat, over current stall, over voltage stall, phase loss (options), external fault, communication fault, PID feedback abnormity, PG fault.
IGBT temperature displayDisplay of current IGBT temperature
inverter fan controlTemperature of starting the fan can be set. (options)
restart after momentary power lossless than 15ms:continue running More than 15ms:automatic inspection of motor's speed, restart after transient power down.
speed starting pursue modeinverter pursue motor speed automatically before starting
parameter protection functionprotect inverter's parameter by setting password and decode

 

PI7800 SERIES AC drives

Ads by Google


About Us | Contact Us | Help | Terms & Conditions
Hot Products: A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | 0-9
Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.