Special Inverter designed for pump One drives one Both for single pump and Mult-Pump System Friendly Interface,Easy Operation
Main Features
1. Automatic control of constant water pressure
2.Set the pressure directly in the operator.
3.Built-in pressure or flow sensors, water level switch signal interface.
4 P.I.D control unattended automatic monitoring of water pumps stoped function (dormant).
5.No need to configure the PLC can realize automatic alternating pump function.
6. Power outages or low water level automatically actived after the restore operation.
7.Cooling fans start and stop is controlled by the internal temperture to extend fan service life.
8.Automatical Switch-Over run-hour, that balance working hours to protect the pump and prolong service life of pump
9. Apply to the use of cold regions of antifreeze function,the application of the cold winter areas.
10.Adequate operation status monitoring, and complete motor protection features, simple operation, compact size to save space.
11.To adapt to a variety of sensor signals:
Pressure sensors, transmissible pressure gauge, eletric contact pressure gauges and pressure switches
Power Range:
Single phase 220~240V 0.5HP-10HP(0.37KW-2.2KW)
Three phase 220~240V 0.5HP-7HP(0.37KW-5.5KW)
Three phase 380~440V 0.5 HP-10HP(0.37KW-7.5KW)
Specification
B600 series | 2001 | 2002 | 2003 | 2005 | 2007 | |
Voltage | 1or3φ200V-240V | 3φ200V-240V | ||||
Capacity(KW) | 0.75 | 1.5 | 2.2 | 3.7 | 5.5 | |
Rated output vol.(V) | 3φ 220V-240V | |||||
Rated output curret A | 4.3 | 7.0 | 10.5 | 14 | 19.6 | |
B600 series | 4001 | 4002 | 4003 | 4005 | 4007 | 4010 |
Voltage | 3φ 380V-440V | |||||
Capacity(KW) | 0.75 | 1.5 | 2.2 | 3.7 | 5.5 | 7.5 |
Rated output vol.(V) | 3φ 380V-440V | |||||
Rated output curret A | 2.2 | 4.1 | 5.8 | 9.5 | 13 | 16 |
Control mode | Sine wave PWM control(V/F) | |||||
Output frequency range | Maximum 500Hz | |||||
Frequency resolution | Analog input volume:0.1Hz | |||||
Overloading capacity | Rated output current 150%-1 minute 175%-2 seconds | |||||
Transmitter signal | 4~20mA/0-10V | |||||
No.of V/F Patterns | Random V/F curve | |||||
Location | Indoor(protected from corrosive gases and dust) | |||||
Ambient temperature | -10~40°C (If beyond the allowable degree,one degree will Derogate 5% output current) | |||||
Storage temperature | -40~60°C | |||||
Environmental temperature | 95%(without dew gather) | |||||
Vibration | 2M/S2 (0.2G) | |||||
Protection rate | IP21 |