to remove the sulfur from gas.
A. Main Specification of Desulfuration Tower
1 | Type | DN800~DN1400 |
2 | Max. Working Temperature () | 60 |
3 | Regeneration Temperature () | ≤60 |
4 | Working Pressure (Mpa) | 0.3~1.6 |
5 | Capacity (Nm3/h) | 1000~3000 |
6 | H2S Content (In / Out) (mg/Nm3) | 3000~≤6 |
7 | Desulfuration Agent | CT8-6B Special |
8 | Volume m3 | 3.0~12.0 |
9 | Structure | Vertical |
10 | Adsorbing & Regenerating Cycle (days) | 80 |
11 | Fixing mode | Outdoor & fixed |
B. Main Component
No. | Name | Type & Specification | Qty | Manufacturer |
1 | Pressure Gauge | Model: Y-150 Class: 1.5 Pressure: 0~4MPa | 1 Piece | Shanghai Yichuan Instrument Co. |
2 | Stop Valve for Pressure Gauge | Model: JJM1-64 Dg6 | 1 Piece | Jiangsu Funing Kaisheng Valve Co. |
3 | Desulfuration Agent | Model: CT8-6B |
| Luzhou Tianxiang Chemic & Industry Developing Co. |
4 | Dual Metal Thermometer | Model: WSS-511 Temperature Range: 0~100 | 1 Piece | Chonqing clinical thermometer Co. |
5 | Stop Valve | Model: J41H-25 Dg50 | 3 Pieces | Zigong Industry Valve Manufacturing Co. |
6 | Relief Valve | Model: A4ZY-40 Dg50 | 1 Piece | Sichuan Kaici Valve Manufacturing Co. |
thionizer/desulfurizer/desulfurize tower