Room Humidity Transmitters 5% or 3% indicates
Room Humidity Transmitters 5% or 3% indicates

Indoor Humidity measurement/ Room Humidity Transmitters. Wide range of temperature probes 0-10V or 4-20mA

Features

          Room Humidity Transmitters

·          Indoor Humidity measurement.

·          Wide range of temperature probes

·          0-10V or 4-20mA measuring signals

·          Compact size and modern design

Applications

·          Indoor humidity measurement for comfort control

Humidity Tansmitter

The transmitter measures the humidity by the honeywell humidity sensor HIH-3610. The transmitter analog output may be be 0-10V or 4-20mA. And the transmitter include a noise filter.the power suply is large range VDC18V----VDC30V.The humidity transmitter measurement range is 5%-95%.

  Ordering

Ordering number:RH-5U-R or RH-5U-R-T

-5 indicates the humidity transmitter accuracy is 5%; -3 indicates 3%, -2 indicates 2%.

-U  indicates the humiditt transmitter signal out is 4-20mA or 0-10V optional.

-T indicates the humidity transmitter integration with temperature signal out.

For example:RH-5U-R-T

The room humidity and temperature transmitter signal out is 4-20mA or 0-10V optional .

Installation

Mount the humidity transmitter on a flat interior wall of the room to be controlled. Do avoid obstructions such as shelves, curtains and recesses. Do not place near heat sources, draft channels. Do not expose to direct sunlight.

·          When installing the unit, fix the base plate first, connect the electrical connections then hook on the cover and secure it.

·          The end of the conduit at the sensor must be sealed to prevent false measurements due to draughts through the conduit.

·          Connect the wires according to the wiring diagram to the measuring circuit in the cover:

o         If only humidity, the transmitter need three terminal connections,DC24V,Ground and humidity signal out.

o         If  humidity and temperature, the transmitter need four terminal connections, DC24V,Ground , humidity signal out and temperature signal out .

o         The connection signal cable should be shield wires.

Technical Specification

Power suply

Option voltage

VDC18V---VDC30V

Power Cunsumption

Max 2 VA

Signal out

signal

4-20mA or 0-10V

Humudity accuracy

5%

Humudity range

0%-100%

Temperature accuracy

0.5 degree C

Temperature range

0-50 degree C

Sensing element

Capacitive Element:

Range

Accuracy

5%---95%

2%

Connection

Connection Terminals

2.5 mm2

Environment

OperationClimatic ConditionsTemperatureHumidity

To IEC 721-3-3class 3 K5-4070°C<95% r.h.

Transport & StorageClimatic ConditionsTemperatureHumidityMechanical Conditions

To IEC 721-3-2 and IEC 721-3-1class 3 K3 and class 1 K3-4080°C<95% r.h.class 2M2

Standards

          conform according to EMC Standard 89/336/EECEMEI Standard 73/23/EEC

EN 61 000-6-1/ EN 61 000-6-3

Automatic electrical controls for household and similar use

Special requirement on temperature dependent controls

EN 60 730 1

EN 60 730 2 - 9

Pollution Class

Normal acc. To EN 60 730,RoHS compliant

Degree of Protection

IP56 to EN 60 529

Safety Class

III (IEC 60536)

Housing Materials

       Cover & Mounting Plate

Fire proof ABS plastic

General

Dimensions [mm]

Cover: 42 x 112 x 88 (H x W x D)

probe: ø 10 x 200 (Diameter x L)

Weight (including package)

135g

Room Humidity Transmitters 5% or 3% indicates